background image

I.

Valve Assembly 

– The valve assembly can be put together before

proceeding.

1. Install standpipe into hole in trough. Rubber washer is to be

on inside of trough. Tighten nut hand tight to allow for
adjustment after valve assembly is installed.

2. Feed hose up through standpipe and attach to valve bracket.

The hose may be shortened if necessary. Tighten the hose
clamp securely to prevent leaks.

3. The lower front peg on valve bracket should be inserted into

hole on standpipe first. Compress valve clip to snap in
opposite hole on standpipe.

4. Remove pin from valve assembly.

5. Install float assembly on valve assembly using previously

removed pin.

6. Rotate standpipe in trough until center of float aligns with

center of trough. DO NOT allow float to be too close to cover
when installed as this may hamper valve performance.

7. Tighten standpipe nut hand tight plus one-quarter turn. Use no

joint compound for this fitting.

J. Cable Heater –  Uncoil cable heater and loop around the valve.

Attach the

 remaining part of the cable heater to the water supply, as far down

the riser tube as possible with the cable twist ties provided. This heater is

water tight, but should not be immersed in water. Heater may cross over

itself, but should not be tightened at those locations.

CAUTION: Installation must not cause any strain on heater 

wiring connections. Avoid heater damage caused by hot spots 

due to its leads lying too close to each other. Also, do not wrap 

additional insulation around heater.

 

K.

Valve Frame and Cover

 – (Omni 3 & 5) Before

installing the valve chamber frame, the weather seal

must be installed on the frame (see diagram).  The seal

is installed by removing the paper backing from the

adhesive side and then starting at the midpoint of the

frame leg; attach the seal to the frame.  Work your way

around the frame with the seal as close to the inside edge

as possible and then up the other leg to the halfway point.

At this time cut any extra foam seal as needed then repeat

for other side.  The frame can then be attached to the casing using the screws and nuts provided in parts bag. A 

washer should be used on the head of the screw as well as under the nut. Tighten securely.

 

OmniFount Large Series Instruction Manual

3

August 13, 2022

Содержание Fresh Water For Life OmniFount 5

Страница 1: ...ng fountain on the market This unit is built to give you excellent service when properly installed and maintained Please follow instructions carefully Read and understand all instructions before insta...

Страница 2: ...a stop and waste valve can be installed below frost level to drain water when unit is not in use Vertical supply line must be centered in riser tube to provide an air space between the line and froze...

Страница 3: ...ze of your animals when determining the dimensions of your platform The concrete step and platform should slope away from the fountain for drainage A rough broom finish to concrete surface provides be...

Страница 4: ...cable heater to the water supply as far down the riser tube as possible with the cable twist ties provided This heater is water tight but should not be immersed in water Heater may cross over itself...

Страница 5: ...warmer than desired turn the thermostat down If there is ice forming on the surface of the water turn the thermostat up Only slight adjustments should be made to the thermostat at any time A 1 16 tur...

Страница 6: ...fter the water and debris has drained reinstall the plug and let the tank refill Now is a good time to readjust the float if needed Reinstall cover and you are done Ritchie Valves Ritchie valves come...

Страница 7: ...ed in riser tube Check that riser tube is free of water and mud that may freeze Check that flexible hose does not touch side of casing or frame Check casing for air leaks Check for air gaps between ca...

Страница 8: ...of a moisture resistant exterior grade outlet is recommended in these units Do not use extension cords CABLE HEATER 240V TROUGH HEATER 240V THERMOSTAT FENWAL OR DISC WARNING CHECK NAMEPLATE FOR CORRE...

Страница 9: ...pkg 20 18633 Plug 3 Water Channel 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074...

Страница 10: ...el 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS...

Страница 11: ...el 2 pkg 1 pkg 7 16534 Fenwal Thermostat SS pkg 1 pkg NS 12583 Valve Supply Line pkg 1 pkg 18320 O Ring Fenwal 6 pkg 1 pkg NS 13830 Cable Htr 120V 48W 1 pkg 1 pkg 18074 Nut Brass Fenwal 6 pkg 1 pkg NS...

Страница 12: ...r to any product that is installed and or used contrary to Ritchie Industries installation instructions and instructions for use The limited warranty shall also not apply to any product whose exterior...

Страница 13: ...This page intentionally left blank OmniFount Large Series Instruction Manual 12 August 13 2022...

Страница 14: ...Part 18735 August 13 2022...

Отзывы: