Table 8-9 List of Risen module loads with tracking system
Cla
ssif
icat
ion
Installation
Module
NEXTracker NX
Horizon
ATI DuraTrack™HZ
Tracking System
Arctech solar
installation bracket
Short
rail
Short rail
+bumper
Short
rail +
suppl
ement
rail
400
mm
clamp
600
mm
clamp
850
mm
clamp
1300
mm
clamp
C1
C2
C3
M
o
n
o
faci
al
mo
d
u
le
RSM72-6-xxxP/MDG
±2400
±3000
/
±1800
±2400
﹢
3000
-2400
﹢
3600
-2400
/
/
/
RSM144-6-xxxP/M
±1600
/
/
±1600
±1600
/
/
/
/
/
RSM144-6-xxxP/MDG
±2400
±3000
/
±1800
±2400
﹢
3000
-2400
﹢
3600
-2400
/
/
/
RSM144-6-xxxMB
±1600
/
/
±1600
±1600
/
/
/
/
/
RSM156-6-xxxP/M
±1600
/
/
±1600
±1600
/
/
/
/
/
RSM120-7-xxxP/M
±1600
/
/
±1600
±1600
/
/
/
/
/
RSM144-7-xxxP/M
±1600
/
/
±1600
±1600
/
/
/
/
/
C1
400mm pitch hole installation
C2
inner four hole installation
C3
outer four hole installation
Risen module can be installed and used on the tracking
system, and the installation hole position or clamp
position shall be selected according to the design of
the support system. Please refer to section Table 8-9 for
details
;
The system installer or professional designer shall
recheck the bearing capacity of the support system
(photovoltaic support, foundation, etc.) according to
the selected installation hole position or pressing block