Page:NO.9 ,Total 41
module in a place without any supports or fixtures.
Never handle and move the module via the cable or the J-Box at any time. At least 2
personnel with non-slip gloves are required to handle one module at the same time.
Do NOT carry the module via overhead and do NOT handle the stacked modules for
moving.
Please store the modules in a ventilated, rainproof and dry place when the
temporary storage is needed.
Please ensure all the modules and electrical contact parts are clean and dry in the
installation.
Do NOT install any module when it is raining, snowing and strong windy.
Artificially concentrated sunlight shall NOT be directed on the module.
Use durable, rust-resistant and UV-resistant materials to fabricate the module
bracket structures which have been tested, certified and approved.
When the modules were installed on the brackets, the brackets structure should
have the ability to bear the wind load and snow load at site. And please ensure
these load will not exceed the maximum load design of the module.
The modules with the glass broken or the back-sheet damage cannot be repaired
and CANNOT be used, there will be the electrical shock risk in case to touch the
surface or frame of these kind of modules. Do NOT try to disassemble the module,
and do NOT remove or damage the module nameplate and any other parts of the
module.
It is FORBIDDEN to stand on the modules in the installation progress, and do NOT
damage or scratch the glass surface of the module.
Do NOT apply any paint or glue to the module glass surface.
The Solar PV modules will generate the electrical power when exposed to the
sunlight, and this power is sufficient to cause fatal electrical shock and burning