background image

4

 

Wireless Sounder Instructions

 

 

Mounting the Sounder

 

1.  Release the mounting bracket captive locking screw (Fig 1). 
2.  Turn the mounting bracket counterclockwise and separate it from the sounder. 
3.  Hold the mounting bracket against the wall (direction arrow pointing up) and mark the 

locations of the mounting holes (Fig. 2).

 

Drill the desired mounting holes and insert 

screw anchors (if required).  

 

NOTE:

 

Do not drill through the mounting bracket. 

4.  Mount the bracket to the wall using the supplied screws. 
5.  Insert  the  supplied  batteries  into  the  battery  chambers  (speaker  and  radio)  paying 

attention to the polarity (Fig 3). 

6.  Perform communication set up with the control panel (see Sounder/Receiver 

Communication Set up paragraph). 

7.  Once communication setup is completed, mount the sounder to the mounting bracket 

by turning the sounder clockwise. Pay attention to the tamper switch. 

8.  Secure the captive locking screw.  

Mounting  

Bracket

Tamper 

Protection

Screw

 

Fig. 1 

Fig. 2 

Speaker 

Batteries

(6V, Serial 

Connection)

Radio 

Batteries

(3V, Parallel 
Connection)

Tamper

Speaker

Fig. 3 

Содержание WL S42

Страница 1: ...Indoor Wireless Sounder Model WL S42 Installation and Programming Instructions...

Страница 2: ...1 Sounder Receiver Communication Set up 5 Step 2 Setting the Sounder Parameters 5 Adjusting the Volume 5 Muting Tamper 6 Setting Supervision Time 6 Pre Alarm indication 6 Step 3 Testing the Sounder 7...

Страница 3: ...tion is sent to the panel There are 2 types of low battery indications Radio low battery Speaker low battery Supervision Each sounder can be defined to be supervised by the panel The system generates...

Страница 4: ...bracket 4 Mount the bracket to the wall using the supplied screws 5 Insert the supplied batteries into the battery chambers speaker and radio paying attention to the polarity Fig 3 6 Perform communica...

Страница 5: ...t two speaker batteries into the batteries chamber Fig 3 5 Insert three Radio batteries into the batteries chamber 6 After a squawk is heard you have 10 seconds to press on the tamper switch for at le...

Страница 6: ...ast once during the receiver supervision time the system will regard the accessory as lost NOTE The receiver supervision time should be higher than the sounder supervision time in order to eliminate f...

Страница 7: ...nit 1 Calibration LightSYS V2 40 and above Engineer menu 7 Install 2 WL Device 1 RX Calibration Diagnostics The Diagnostics menu enables to test parameters reflecting the operation of the sounder Spea...

Страница 8: ...e captive screw and remove the sounder from the mounting bracket by turning it counterclockwise 3 Remove the old batteries from the metal clips and replace with new ones Pay attention to the polarity...

Страница 9: ...pe Two Way Narrow band Frequency 868 MHz or 433MHz Range up to 150m 492 Line of sight Supervision Yes Modulation Type ASK Environmental Temperature 10 C to 55 C 14 F to 131 F IP Rating IP 31 IK 06 Env...

Страница 10: ...the customer Return Material Authorization In the event that you need to return your Product for repair or replacement RISCO will provide you with a Return Merchandise Authorization Number RMA as well...

Страница 11: ...present that the Product may not be compromised or circumvented that the Product will prevent any personal injury or property loss by burglary robbery fire or otherwise or that the Product will in all...

Страница 12: ...roup com Italy Tel 39 02 66590054 support riscogroup it USA Tel 305 592 3820 support riscogroupusa com Spain Tel 34 91 490 2133 support es riscogroup com China Tel 86 21 52 39 0066 support cn riscogro...

Отзывы: