WatchIN Installation Manual
17
English
DIP Switch Settings
DIP Switch
Number
Description
1 - 5
Used to set the detector ID number. Set the ID number in the same way as for
any other ProSYS accessory (Refer to the table below).
6 - 10
Not used
WatchIN ID: DIP Switches 1 - 5
ID
1
2
3
4
5
ID
1
2
3
4
5
01
OFF OFF OFF OFF OFF
17
OFF OFF OFF OFF ON
02
ON OFF OFF OFF OFF
18
ON
OFF OFF OFF ON
03
OFF ON OFF OFF OFF
19
OFF ON OFF OFF ON
04
ON ON OFF OFF OFF
20
ON
ON OFF OFF ON
05
OFF OFF ON OFF OFF
21
OFF OFF ON
OFF ON
06
ON OFF ON OFF OFF
22
ON
OFF ON
OFF ON
07
OFF ON ON OFF OFF
23
OFF ON ON
OFF ON
08
ON ON ON OFF OFF
24
ON
ON ON
OFF ON
09
OFF OFF OFF ON
OFF
25
OFF OFF OFF ON
ON
10
ON OFF OFF ON
OFF
26
ON
OFF OFF ON
ON
11
OFF ON OFF ON
OFF
27
OFF ON OFF ON
ON
12
ON ON OFF ON
OFF
28
ON
ON OFF ON
ON
13
OFF OFF ON ON
OFF
29
OFF OFF ON
ON
ON
14
ON OFF ON ON
OFF
30
ON
OFF ON
ON
ON
15
OFF ON ON ON
OFF
31
OFF ON ON
ON
ON
16
ON ON ON ON
OFF
32
ON
ON ON
ON
ON
ProSYS Programming
(from ProSYS software
version 7.xx and above)
The following section describes the additional software programming options, added to the
ProSYS software, that concern the settings of the WatcIN DT as a BUS detector. Up to 32 BUS
detectors can be added to the system (16 in ProSYS 16) and each of them comes at the expense
of a zone in the system.
It is recommend reading and fully understanding the ProSYS Installation and User Manuals,
before programming the WatchIN.
Notes:
The WatchIN is compatible with the ProSYS software Version 7.xx and above.
The WatchIN can be programmed via the U/D Software supporting ProSYS software Version 7.xx and above.
For maximum operation stability, it is best NOT to exceed a total of 300 meters (1000 feet) of wiring when
connecting the WatchIN to the BUS.
Adding / Deleting the WatchIN DT
The WatchIN is part of an accessory category, BUS zones. Therefore, Adding/Deleting the
WatchIN is identical to any other accessory with the following exception:
Each BUS Zone Detector should be assigned to a Regular Zone
.
Any BUS detector can be assigned to a physical wired zone or to a virtual zone
.
Physical zone
: Any zone on the ProSYS PCB (zones 1-8) or on a wired zone expander
(ZE08, ZE16).
Virtual zone
: Any zone on a BUS zone expander defined as BZ08 or BZ16.
Notes:
Virtual BUS zones are cost effective. They enable to expand your system zones without adding physical zone
expanders.
The virtual BUS zone expander can be used only for BUS zone detectors.
To add a BUS zone expander select type BZ08 or BZ16 when adding a zone expander (Quick key [7][1][2]).
Содержание RK325DT0000D
Страница 2: ...2 WatchIN Installation Manual ...
Страница 21: ...WatchIN Installation Manual 21 English ...
Страница 40: ...40 Manuale di Installazione WatchIN ...
Страница 60: ...60 Guide d installation WatchIN ...
Страница 91: ...Instruções de Instalação WatchIN 91 Portuguese Figura 9 ...