5
[Command Class Multilevel Switch, Multilevel Switch Report,
Value = 0x63/0xFF(TOP)]
3-3 MULTILEVEL SWITCH START LEVEL CHANGE:
This is the command which user can move the shutter up to the top or down to
the bottom.
[Command Class Multilevel Switch, Multilevel Switch Start Level Change,
Up/Down Value]
3-3.1 Up/Down Bit:
If Up/Down Bit=0x00 Shutter move up
If Up/Down Bit=0x01 Shutter move down
If Up/Down Bit=0x03 no move
[Command Class Multilevel Switch, Multilevel Switch Start Level Change,
Up/Down=0x00] control the shutter to the top (0xFF)
[Command Class Multilevel Switch, Multilevel Switch Start Level Change,
Up/Down=0x01] control the shutter to the bottom (0x00)
[Command Class Multilevel Switch, Multilevel Switch Start Level Change,
Up/Down=0x03] Don't move the shutter or stop the moving shutter
ATT. 1. Ignore_Start_Level
、
Start_Level
、
Dimming_Duration
、
Inc/Dec
、
Step_size
can not be used.
2
. PAN08 can not control the speed of motor.
3. It may have some distance error caused by motor start up time.
4. If user found the error become significant, you may using S1 or S2 move
shutter to the end or remote move shutter to 0% and 100%, and that will
automatically calibrate this error.
3-3.4 MULTILEVEL SWITCH STOP LEVEL CHANGE:
When receive Multilevel Switch Stop Level change Command PAN08 will stop the
motor.
4 SCENE ACTIVATION COMMAND CLASS
4-1 Scene Activation Set Command
:
When PAN08 receive Scene Activation Set command, it will read the level of the
pre-configured Scene ID from EEPROM. And it will be controlled as a Multilevel
Switch Set command that described in 3-1. The Dimming Duration of the command
will be ignored because PAN08 can not control the speed of motor.
5 SCENE ACTUATOR CONFIGURATION COMMAND CLASS
5-1 Scene Actuator Configuration Set Command
:
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Set, Scene ID=1~255, Override bit=0, Level=0~99 or 255]
The current setting of PAN08 will not be override.
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Set, Scene ID=1~255, Override bit=1, Level=0~99 or 255]
The Level value in this Command is associated to the Scene ID.
5-2 Scene Actuator Configuration Get Command
:
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Get, Scene ID=1~255 ]
[Command Class Scene Actuator Configuration, Scene Actuator Configuration
Report, Scene ID=1~255, Level=0~99 or 255, Dimming Duration=0~0xFE]
Report the Pre-configured Scene ID of PAN08.