Risco PAN08-1B Скачать руководство пользователя страница 4

mean the Shutter is bottom down, if the report value is 0xFF that mean the Shutter is 

at the top. But if report value is 0xFE means the position is unknown. 

 

Binary Switch Get Command

 

[Command Class Binary Switch, Binary Switch Get] 

Binary Switch Report Command

 

[Command Class Binary Switch, Binary Switch Report, Value = 0x00 
(BOTTOM)] 

[Command Class Binary Switch, Binary Switch Report, Value = 0xFE 
(UNKNOWN)] 

[Command Class Binary Switch, Binary Switch Report, Value = 0xFF(TOP)]

 

 

2-2 BINARY_SWITCH_SET 

PAN08 can only accept Binary Switch Set Command which value is either (0x00) 

Bottom or Top (0xFF), other value is not acceptable.

   

 

[Command Class Binary Switch, Binary Switch Set, Value = 0xFF(255)] 

control the shutter to the top (0xFF). But if the shutter is on the way down, this 
command will stop the shutter. 

[Command Class Binary Switch, Binary Switch Set, Value = 0x00(0)] 

control the shutter to the bottom(0x00). But if the shutter is on the way up, this 
command will stop the shutter.

 

 

3. Multilevel Switch Command Class (Version 3)

 

3-1 MULTILEVEL SWITCH SET

PAN08 can accept Multilevel Switch Set Command which value is either (0x00) 

Bottom or Top (0x63 or 0xFF) or (0x01-0x62) the position between TOP and Bottom. 

Other value (0x64-0xFE) is not acceptable

 

[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x63 or 

0xFF(255)] control the shutter to the top (0xFF) 

[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x00(0)]                 

control the shutter to the bottom(0x00) 

[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x01-0x62]       

control the shutter to the position between Bottom and Top.

 

3-2 MULTILEVEL SWITCH GET

:

 

When PAN08 receive Multilevel Switch Get Command, it will send Multilevel Switch 

Report Command to report the position of the shutter. When the report value is 0x00, 

that mean the shutter is at the Bottom, if the report value is 0x63 or 0xFF that mean 

the shutter is at the top, any other value between 0x01~0x62 imply shutter at the 

position between top and bottom.

 

 

Switch Multilevel Get Command

 

[Command Class Multilevel Switch, Multilevel Switch Get] 

Multilevel Switch Report Command

 

[Command Class Multilevel Switch, Multilevel Switch Report,   

Value = 0x00(BOTTOM)] 

[Command Class Multilevel Switch, Multilevel Switch Report,   

Value = 0x01~0x62(Between BOTTOM and TOP)] 

Содержание PAN08-1B

Страница 1: ...WaveTM Network In the front casing there is an include button with LED indicator below which is used to carry out inclusion exclusion reset or association When first power is applied its LED flashes...

Страница 2: ...elease yet No node ID Under normal operation when the PAN08 has not been allocated a node ID the LED flashes on and off alternately at 2 second intervals By pressing S1 S2 or Include button it will st...

Страница 3: ...ter is at the Bottom if the report value is 0x63 or 0xFF that mean the shutter is at the Top any other value between 0x01 0x62 imply Shutter at the position between top and bottom Basic Get Command Co...

Страница 4: ...AN08 can accept Multilevel Switch Set Command which value is either 0x00 Bottom or Top 0x63 or 0xFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 0xFE is not acceptable Command Cla...

Страница 5: ...and that will automatically calibrate this error 3 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE When receive Multilevel Switch Stop Level change Command PAN08 will stop the motor 4 SCENE ACTIVATION COMMAN...

Страница 6: ...nsumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Comman...

Страница 7: ...nd Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF It mea...

Страница 8: ...Report Period If the setting is configured for 1hour set value 720 the PAN08 will report its instant power consumption every 1 hour to the node of Group 1 The maximum interval to report its instant p...

Страница 9: ...oving short pressed S1 again the shutter just keep moving up toward TOP 0xFF The easy way to stop this moving is short pressing S2 When S2 is short pressed the shutter will move down toward BOTTON 0x0...

Страница 10: ...king indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recyc...

Страница 11: ...t 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen...