Risco PAN08-1B Скачать руководство пользователя страница 2

2.    Pressing Include button three times 

within 2 seconds will enter inclusion 
mode.

 

Exclusion 
(Remove an 
existed node) 

1.  Put your Z-Wave controller into 

exclusion mode by following the 
instructions provided by the 
controller manufacturer. 

One press one flash LED 

2.  Pressing Include button three 

times within 2 seconds will enter 
exclusion mode. 

Node ID has been excluded. 

LED 0.5s On, 0.5s Off 
(Enter auto inclusion) 

Reset 

1.  Pressing Include button three times 

within 2 seconds will enter inclusion 
mode. 

Use this procedure only in 
the event that the primary 
controller is lost or 
otherwise inoperable. 

2.  Within 1 second, press Include 

button again for 5 seconds. 

3.  IDs are excluded. 

LED 0.5s On, 0.5s Off 
(Enter auto inclusion) 

Association 

1.    The PAN11 is an always listening 

Z-Wave device, so associations 
be added or removed by a controller 
at any time. 

Or    If your controller requires to have 

the PAN11 send a 'node information 
frame' or NIF for associations, 
pressing the On/Off button three 
times within 2 seconds will cause 
the PAN11 to send its NIF. 

LED One press one flash 

2.    There are 1 group (Group 1) for the 

PAN08 

 

Adding a node ID allocated by Z-Wave Controller means inclusion. Removing a node ID 

allocated by Z-Wave Controller means exclusion.

 

Failed or success in including/excluding the node ID can be viewed from the Z-Wave 

Controller. 

 

 
LED Indication

 

To distinguish what mode the PAN08 is in, view from the LED for identification. 
 

State Type 

LED Indication 

Motor 
activate 

No matter up or down, close or open, Led will flash every second 
while Motor activate. 

When S1 or S2 close to L, the LED will flash even when the motor 
stop by itself, this is to let user know the S1 or S2 still close and not 
been release yet. 

No node ID 

Under normal operation, when the PAN08 has not been allocated a 
node ID, the LED flashes on and off alternately at 2-second 
intervals. By pressing S1 S2 or Include button, it will stop flashing 
temporarily. 

Learning 

When PAN08 is in learning mode, LED flashes on and off 
alternately and repeatedly at 0.5 second intervals.

 

Overload 

When overload state occurs, the PAN08 is disabled and LED 
flashes on and off alternately at 0.2 second intervals. PAN08 will 
send alarm_type=8    alarm_Level=0xFF to Group1, Overload state 
can be cleared by disconnect and reconnect the PAN08 to the main 
power

 

 

Choosing a Suitable Location 
 

1.  Do not locate the PAN08 facing direct sunlight, humid or dusty place. 
2.  The suitable ambient temperature for the PAN08 is 0°C~40°C. 
3.  Do not locate the PAN08 where exists combustible substances or any source of 

heat, e.g. fires, radiators, boiler etc. 

4.  After putting it into use, the body of PAN08 will become a little bit hot of which 

phenomenon is normal.

 

 
Moving Range Calibration 
 

1.  It  is  important  to  carry  out  a  shutter  calibration  process  before  you  control  the 

shutter to move. Press inclusion button over 3 seconds and release before the 6th 
second,  the  roller  shutter  controller  will  start  the  shutter  calibration  process.  The 
process is composed of three continue stages. The shutter move to the TOP in first 
stage, and move to the BOTTOM in second stage, and move to the TOP again in 
third stage. Then PAN08 will know the total range of UP and DOWN. 

 
2. During the shutter calibration process, any emergencies happen you can press 

and release the include button to stop the process. 

 
3. If user found the direction is reverse, this may cause by the wrong connection of 

NC and NO to the motor, please exchange NC and NO connection and execute 
calibration process again. 

 
4. For safe issue, please select the motor which can stop by itself when go to bottom 

end or top end. 

Содержание PAN08-1B

Страница 1: ...WaveTM Network In the front casing there is an include button with LED indicator below which is used to carry out inclusion exclusion reset or association When first power is applied its LED flashes...

Страница 2: ...elease yet No node ID Under normal operation when the PAN08 has not been allocated a node ID the LED flashes on and off alternately at 2 second intervals By pressing S1 S2 or Include button it will st...

Страница 3: ...ter is at the Bottom if the report value is 0x63 or 0xFF that mean the shutter is at the Top any other value between 0x01 0x62 imply Shutter at the position between top and bottom Basic Get Command Co...

Страница 4: ...AN08 can accept Multilevel Switch Set Command which value is either 0x00 Bottom or Top 0x63 or 0xFF or 0x01 0x62 the position between TOP and Bottom Other value 0x64 0xFE is not acceptable Command Cla...

Страница 5: ...and that will automatically calibrate this error 3 3 4 MULTILEVEL SWITCH STOP LEVEL CHANGE When receive Multilevel Switch Stop Level change Command PAN08 will stop the motor 4 SCENE ACTIVATION COMMAN...

Страница 6: ...nsumption Watt of Switch When receiving Meter Get Command it will report Meter Report Command to the node asked Meter Get Command Command Class Meter Meter Get Scale 0x02 W Meter Report Command Comman...

Страница 7: ...nd Command Class Meter Meter Report Rate Type 0x01 Meter Type 0x01 Precision 2 Scale 0x06 Size 1 Bytes Meter Value PF Example Scale 0x06 PF Precision 2 Size 1 1 Byte of PF Meter Value 1 0x63 PF It mea...

Страница 8: ...Report Period If the setting is configured for 1hour set value 720 the PAN08 will report its instant power consumption every 1 hour to the node of Group 1 The maximum interval to report its instant p...

Страница 9: ...oving short pressed S1 again the shutter just keep moving up toward TOP 0xFF The easy way to stop this moving is short pressing S2 When S2 is short pressed the shutter will move down toward BOTTON 0x0...

Страница 10: ...king indicates that this product should not be disposed with other household wastes throughout the EU To prevent possible harm to the environment or human health from uncontrolled waste disposal recyc...

Страница 11: ...t 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interferen...

Отзывы: