9
Step 6: Performing a Walk Test
1
Figure 10
The detector automatically enters walk test mode for 10 minutes following tamper
closure. Walk through the entire protected area and observe the LEDs to confirm full
coverage (
see LED Status
).
2
Manually initiate a walk test:
Select User Menu: 5) Maintenance > 1) Walk Test > Select Full Walk Test or Quick Walk
Test. The detector remains in walk test mode until any key on the panel is pressed.
Note:
The LEDs switch off after Walk Test to avoid a situation of mapping the detection zone
and to extend battery life.
Step 7: MW Range Adjustment
1
Over power
2
Under power
3
Correct adjustment
A
Detector
B
Corridor
Anti-Mask Calibration
Following tamper closure, the anti-mask calibration procedure begins (up to 2 minutes). For
successful calibration, make sure that there are no objects near the detector for the duration of the
procedure.
1
2
3
A
B