background image

21

DIAgNostICs - IN.K 1000 error CoDes

The error codes indicate a failure or problem that must be rectified to guarantee the good function of the 

n.YJ2 

control 

system. The error messages listed below display on the keypad. For more information on error messages. 

Please refer to the IN.YE5

 control 

system techbook at 

www.geckodocs.com 

If this guide does not help you solve the problem please contact your dealer. 

error CoDe 

MessAge

AOH 

ElEvATEd INTErNAl TEmPErATurE

CFLO 

NO FLOw CONdITION

COmm 

VerIFy CabLe CONNeCTIONs

er1 

swImspa CONFIg. : sLaVe uNIT Is mIssINg

F1 

IN.xm2 Fuse # 1 Is bLOwN

F2 

IN.xm2 Fuse # 2 Is bLOwN

F3 

IN.xm2 Fuse # 3 Is bLOwN

FLC 

The pressure swITCh Is CLOsed

FLO 

NO FLOw CONdITION FOr mOre ThaN 2 hOurs

FLO 

NO FLOw CONdITION

hIbr 

add Fresh waTer TO The spa

hL 

hIgh LImIT CIrCuIT has TrIpped!

hr 

hardware errOr was deTeCTed (ThermaL Fuse)

hr 

a hardware errOr was deTeCTed (reLay sTuCk)

LObr 

add brOmICharge TO spa waTer

NObr 

add brOmICharge TO spa waTer

Oh 

spa TemperaTure Is TOO hIgh

pr 

Temp prObes Or deTeCTION CIrCuIT are deFeCTIVe

rh Id 

IN.xm2 aNd IN.Therm INCOmpaTIbLe

rh NC 

COmm. errOr beTweeN IN.xm2 - IN.Therm

sC er 

errOr deTeCTed durINg The LearNINg mOde

sp IN 

INpuT VOLTage Issue

supp 

CONNeCT pOwer COrd TO 240 V sOurCe

upL 

The spa paCk dOes NOT haVe VaLId sOFTware. pLease INserT VaLId    

 

IN.sTICk TO reprOgram spa paCk.

TROUBLESHOOTING GUIDE

1

too much water on display

wipe screen

This message appears when too much water is 

detected on the touch screen. Simply wipe away 

excess water.

installation error messages

Upon connecting the in.k1000 to your spa system you may see one of two error messages.  

Please follow the instructions in the message or contact your dealer for more information.

Error messages on-screen list and definitions:

http://geckokeypads.com/k1000errormessages/

9919-101453-C 

Rev. 02-2017

www.geckoalliance.com

© Groupe Gecko Alliance Inc., 2017
All trademarks or registered trademarks are the property of their respective owners.

Printed in Canada 

1

too much water on display

wipe screen

This message appears when too much water is 

detected on the touch screen. Simply wipe away 

excess water.

installation error messages

Upon connecting the in.k1000 to your spa system you may see one of two error messages.  

Please follow the instructions in the message or contact your dealer for more information.

Error messages on-screen list and definitions:

http://geckokeypads.com/k1000errormessages/

9919-101453-C 

Rev. 02-2017

www.geckoalliance.com

© Groupe Gecko Alliance Inc., 2017
All trademarks or registered trademarks are the property of their respective owners.

Printed in Canada 

Содержание Nautilus 5.8

Страница 1: ...Riptide Nautilus 5 8 IN GROUND EXERCISE POOLS Owner s Manual...

Страница 2: ...ation 18 Audio mode 19 On off 19 Speakers setting 19 Audio source selector 19 Disconnect Bluetooth 19 Variable speed drive control panel 20 Other functions 20 Freeze protection 20 Clean cycle 20 Circu...

Страница 3: ...Riptide Nautilus 5 8 TURBO IN GROUND 3 Riptide nautilus 5 8 turbo Riptide nautilus 5 8 turbo Pro...

Страница 4: ...a a The use of alcohol drugs or medication can greatly increase the risk of fatal Hypothermia in a pool b The causes symptoms and effects of Hypothermia may be described as follows Hypothermia occurs...

Страница 5: ...excessive water may contact the pool such as from sprinklers or a roof edge without rain gutters If possible avoid areas of direct prolonged sunlight The ultraviolet rays of sunlight will tend to fad...

Страница 6: ...er from over filling the pool Excess water will flow out from the corner adjacent to the overflow Note 1 The higher the water level the less pool users it will take to cause the water to overflow the...

Страница 7: ...ough the service hatch to repair or replace as needed The only consideration here is that your electrician will need to supply a suitable cable with a waterproof gland to pass through the fiberglass w...

Страница 8: ...pool base Ensure that the ground around the pool is drainable if not then large soakaways should be constructed to ensure the pool will not flood To avoid the pool floating if any underground water i...

Страница 9: ...il paving slabs decking or tiles as required Covers Covers are essential for keeping your pool both clean and the water hot You can sink your pool up to the lip like the pool installation in the photo...

Страница 10: ...DIAGRAMS 10 Riptide nautilus 5 8 TURBO 1 3HP Single Speed Pump 2 Control Box 3 Ozone Clear Core Chamber 4 Ozone Generator 5 Circulation Pump 6 Control Panel...

Страница 11: ...gle Speed 5 1 Air Check Valve Assembly 6 Two Cylinder Skimmer 7 2 Suction 8 Ozone Injector 9 Swim Jet 10 5 Light Housing 11 2 Infinity LED 12 Large Face Direct Jet Insert 13 Stainless Steel Handrail 1...

Страница 12: ...anytime you wish The Gecko in k1000 capacitive touch screen display keypad fitted to the Nautilus range will operate under wet and rainy conditions Jet control The speed of the jets is fully adjustabl...

Страница 13: ...s the following modes sanitization with in clear connected audio with in stream 2 connected color with in mix installed spa settings To select a mode slide the left wheel up or down until the desired...

Страница 14: ...e the right wheel until the display contrast icon is highlighted in the middle Simply touch the line of the contrast you want to select water temperature The temperature at the bottom of the screen sh...

Страница 15: ...pump configured to run 24 hours the screen will show you the purge setting instead of filtration The purges are pre programmed for a fix number of minutes therefore the duration will be set to N A on...

Страница 16: ...to reset the time once a task has been completed To reset a task select it by pressing the curved arrow then confirm when prompted Once you have confirmed the task will be reset set date Here you can...

Страница 17: ...d he will be prompted again to select a 4 digit code same functionality as a Safe in a hotel room The keypad can be unlocked with a universal unlock code 3732 or by a reset of the keypad miscellaneous...

Страница 18: ...en check mark Swipe Up or Down the list to select your network wifi network password If the wifi network is password protected enter it when keyboard prompts Use Enter key to validate the password If...

Страница 19: ...e fade and subwoofer sliders will only appear on the screen if the corresponding speakers are installed on the in stream 2 turn in stream 2 OFF icon green Press the icon at the center of the screen to...

Страница 20: ...e control Freeze Protection If the sensors within the heater detect a very low temperature the pumps and blower automatically activate to provide freeze protection The pumps and blower will run contin...

Страница 21: ...m incompatible RH NC Comm error between in xm2 in therm SC ER Error detected during the learning mode SP in Input voltage issue Supp Connect power cord to 240 V source UPL The spa pack does not have v...

Страница 22: ...Electric control failure display shows error message The default time setting has switched off the jets The pump motor is overheating The water pump has an air block Filter cartridge needs cleaning Th...

Страница 23: ...SHOCK or double dose of CHLORINE GRANULES MAINTENANCE 3 pH Control Proper pH balance is extremely important in controlling bacteria providing water that s comfortable for the user and in preventing da...

Страница 24: ...s per million 5 Test and adjust the pH to the range of 7 2 7 6 6 After the water has circulated for approximately a quarter of an hour retest the chlorine level in your water and add the correct amoun...

Страница 25: ...Volume Alkalinity Chemical Addition Total alkalinity adjustment required in mg L Metre Effect 10 20 30 40 50 60 70 80 90 100 NAUTILUS 5 8 IN GROUND 9 560 Reduce Sodium Bisulphate pH Reducer 229 44g 4...

Страница 26: ...HEADRESTS Clean on a regular basis with soap water and a clean cloth Use 303 Protectant or it s equivalent once per month This will maintain water resistance and lustre of the product Between uses it...

Страница 27: ...level No use for 1 2 weeks If you plan to not use your pool for 1 2 weeks then we suggest that you not make any changes in operating your pool No use for 2 6 weeks If you plan to not use your pool fo...

Страница 28: ...www riptidespas com...

Отзывы: