background image

4

From the initial screen press the 

SET/STOP

button followed by

the 

DOWN

button. The display will now show this. 

Press the 

SET/STOP

button twice. The display will now show

this,

use the 

UP/DOWN

buttons to select the memory you wish 

to program (0-9). All of these memories are preset during 
manufacture and can be modified as necessary.
Once the required memory is selected press the 

SET/STOP

button followed by the Up button before pressing the

SET/STOP

button again.

This displays the first options screen where the details of 
the battery to be charged can be entered -

- use 

UP/DOWN

buttons to select the required option NiCd, Pb

or NiMH.
Press 

SET/STOP

and the display will show 

battery cells/voltage-use 

UP/DOWN

to set from 1-25 cells

(NiCd/Ni-MH) or Pb from 2-12volt in 2volt increments

Press 

SET/STOP

and the display will show battery capacity 

of pack being charged-can be set for any capacity from 
50-5000mAh in 50mAh increments (NiCd/Ni-MH). Pb from 0.5
to 50.0Ah in 0.5Ah increments.

Press 

SET/STOP

and the display will show charge 

current- NiCd  and Pb can be set from 0.1A to 5.0A in 0.1A
increments. Ni-MH can be set from 0.1A to 5.0A in 0.1A 
increments, however the highest charge rate that the software
will allow is equal to the capacity of the battery. For example,
the highest charge rate allowed for a 3.0Ah battery is 3.0A 
(1C), charge rates lower than this can of course also be used.

Note that the parameters of the battery to be charged must 
be entered on one of the 10 memories before manual 
charging, unless one of the pre-set memories matches exactly.
(see setting battery parameters)

Commence charging/discharging by pressing the charge/
discharge buttons.  When manual charging Nickel Cadmium
batteries the screen will show the battery check screen (see
below) for approximately 3 minutes while the software checks
the battery status and the level of charge already in the battery. 

At the end of this check period the battery charge screen will
appear, with the level of charge which has been detected
appearing as a percentage on the bottom right of the screen. 
This battery check feature can be bypassed by pressing the

SET/STOP

button when the battery check screen appears.

Bypassing the battery check will not allow the level of charge
to be detected, and the charge display screen will commence
at 0% level of charge 

DISCHARGING: NOTE THAT WHEN THE DISCHARGE CYCLE

IS COMPLETED, THERE WILL BE A SHORT PAUSE BEFORE

SUPERNOVA WILL AUTOMATICALLY START TO CHARGE.

AFTER THE CHARGER HAS COMMENCED CHARGING THE

BATTERY IT IS STILL POSSIBLE TO SEE THE DISCHARGE

RESULTS IN THE DATA REFERENCE PROGRAM.

MANUAL MODE (CONT…)

SETTING BATTERY PARAMETERS (1-10 MEMORIES)

SETTING BATTERY PARAMETERS (1-10 MEMORIES) (CONT…)

SuperNova 250S Inst.Update  17/11/03  10:46 am  Page 4