Step 7.
Test the tool operation on a sample cable by hand.
Slowly rotate the tool clockwise around
the cable to remove the insulation. Insulation will peel off the cable until the conductor reaches the stop
bar. The blade will automatically sever the insulation at the end of the cut. Observe the conductor and
insulation condition. The blade depth should be set as conservative as possible, but also deep enough
to produce a clean, square cut. Re-adjust the blade as needed.
To remove the bushing, depress the lock release
pin on the housing and slide the bushing out
46 Nooks Hill Road, Cromwell, CT 06416 USA
~
Phone: 800-528-8665
~
Int’l: (01) 860-635-2200
Fax: (01) 860-635-3631
~
E-mail: [email protected]
~
Internet: www.ripley-tools.com
12959
06-05-14 ff
WARRANTY: RIPLEY warrants its products against defective materials and workmanship for a period of one
year from date of shipment from the RIPLEY factory provided the product is utilized in accordance with
instructions and specified ratings.
Step 8.
The tool is ready for power operation as shown above, or can be operated manually.
SW-2
Ratchet Wrench
REPLACEMENT PARTS
Model
Part #
Blade
Blade
Part #
Rotating Stop
Bar Part #
WS 6
12900 CB 8-2
12903
12928
WS 6 with WA 1 12917 CB 8-2
12903
12928
WS 6 with WA 3 12918 CB 8-2
12903
N/A