01/18
37
7
Options
7.1 Hour counter
This machine is equipped with an hour counter.
The hour counter indicates the number of working hours that the machine has
worked.
7.2 Anti-freeze with anti freeze tank
Your high-pressure device may freeze up during a period of frost. A number of
safety precautions must be taken.
Additional preparations before departure:
1.
Drain the water tank by opening the drain valve (
).
2.
When all water has been removed/drained, you remove the water filter
cap (
).
3.
Clean the filter and mount the cap again.
4.
Close the drain valve (
5.
Close the supply valve (
) water filter.
6.
Fill the anti-freeze tank (
A
) with antifreeze.
7.
Remove the nozzle/gun from the HP hose.
8.
Open the antifreeze valve (
B
).
9.
Press the run dry button
and start the engine.
10.
Check if the HP-valve (
) on the machine is open.
11.
Push button
on the control box.
12.
Let the high-pressure pump remove all the water, which is still in the
high-pressure hose and pump.
13.
Close the high-pressure valve or push button
, when anti
A
B
C