HCM705B
-
High Accuracy Gyro Compass
seconds don’t move, the system will take the nineteenth point.
After took the nineteenth point, again rotate 90 °horizontally,alternate the negative Roll value
R=-15
°
,
please keep this posture for 2 to 3 seconds don’t move, the system will take the
twentieth point.
After took the twenty second point, again rotate
90°horizontally, alternate the positive Roll value
R=+55
°
,
please keep this posture for 2 to 3 seconds
don’t move, the system will take the twenty third point.
After took the twenty third point, again rotate
90 °horizontally,alternate the negative Roll value
R=-55
°
,
please keep this posture for 2 to 3 seconds
don’t move, the system will take the twenty fourth point.
Sending stop command---compass
response---Re-sending save command---compass
response save successfully.
RION’s 3D Software
You can download the RION angle debugging software from RION’s official website for the
preliminary angle debugging, also you Can download public version of the comassistant
software on line for using
Open/Close
:
Open and close COM port;
Com: Select the the device corresponding to the COM port
Address: Fill in the sensor current address code, the factory default is 00