62
Rinnai Direct Vent Service Manual
Checking Micro-amps
RHFE 201, 263, 431, 556 Series
1. Locate the yellow wire from the flame rod. Disconnect at Molex.
2. Set the meter to read micro-amps.
3. Place the meter in series with the flame rod a the disconnected Molex.
4. Operate the appliance and view the flame development in the view window.
5. Read the micro-amps on the meter for high fire and low fire conditions.
NOTE: Volt meters differ in style and configuration. It is the technician’s responsibility to know the tools and how
to set up for operations and testing.
Содержание RHFE-431WTA
Страница 14: ...14 Rinnai Direct Vent Service Manual RHFE 431FA Series RHFE 556FA FTRA Wire Diagram ...
Страница 15: ...Rinnai Direct Vent Service Manual 15 RHFE 556FAIII Wire Diagram ...
Страница 16: ...16 Rinnai Direct Vent Service Manual RHFE 556FTRAIII Wire Diagram ...
Страница 24: ...24 Rinnai Direct Vent Service Manual RHFE 431WTA Wire Diagram ...
Страница 25: ...Rinnai Direct Vent Service Manual 25 RHFE 556WTA Wire Diagram ...
Страница 31: ...Rinnai Direct Vent Service Manual 31 RHFE 551FA Wire Diagram ...
Страница 34: ...34 Rinnai Direct Vent Service Manual RHFE 1001FA Wire Diagram ...
Страница 37: ...Rinnai Direct Vent Service Manual 37 RHFE 1001FA VA Wire Diagram Wire Diagram Block Diagram ...
Страница 42: ...42 Rinnai Direct Vent Service Manual RHFE 201FA Wire Diagram ...
Страница 43: ...Rinnai Direct Vent Service Manual 43 RHFE 201FA Block Diagram ...
Страница 46: ...46 Rinnai Direct Vent Service Manual RHFE 263FA RHFE 263FAII Wire Diagram ...
Страница 47: ...Rinnai Direct Vent Service Manual 47 RHFE 263FA RHFE 263FAII Block Diagram ...
Страница 50: ...50 Rinnai Direct Vent Service Manual RHFE 1004FA Wire Diagram ...
Страница 67: ...Rinnai Direct Vent Service Manual 67 Notes ...