background image

 

 

2 TB-22 

RHFE-431 (FAIII, WTA) and RHFE-556 (FAIII, FTRAIII, WTA) Installation at High Altitude 

Table 1  RHFE-431 (FAIII, WTA)  
 

Pressure Setting (W.C.) 

 

using Natural Gas  

Altitude 

High Fire 

Low Fire 

Less than 2000 

ft (610 m) 

2.40 in * 

(61 mm) 

0.7 in * 

(18 mm) 

2000 - 5000 ft 

(610 - 1524 m) 

2.10 in 

(53 mm) 

0.6 in 

(15 mm) 

* Factory Setting  

10.  Press the SW4 switch to lock in the setting. 

11.  Press the SW3 switch to operate the 

appliance in forced high fire mode. 

12.  Compare the pressure reading on the 

manometer to the correct table for your unit 
and gas type.  If necessary adjust the high 
fire pressure using the 

 and 

 buttons. 

13.  Press the SW3 switch to lock in the setting. 

14.  Press the SW 5 switch to return the appliance 

to normal operation. 

10.  Press the ON/OFF button to turn the 

appliance off. 

11.  Remove manometer and install Allen head 

screws. Operate the unit and check for gas 
leaks at the test points. 

12.  Install front panel. 

Table 3  RHFE-556 (FAIII, FTRAIII, WTA)

Pressure Setting (W.C.) 

 

using Natural Gas  

Altitude 

High Fire 

Low Fire 

Less than 2000 

ft (610 m) 

3.80 in * 

(97 mm) 

0.7 in * 

(18 mm) 

2000 - 10,000 ft 

(610 - 3048 m) 

3.40 in 

(86 mm) 

0.6 in 

(15 mm) 

* Factory Setting  

Table 2  RHFE-431 (FAIII, WTA)  
 

Pressure Setting (W.C.) 

 

using Propane Gas  

Altitude 

High Fire 

Low Fire 

Less than 2000 

ft (610 m) 

2.8 in *           

(71 mm) 

0.8 in *          

(20 mm) 

2000 - 5000 ft 

(610 - 1524 m) 

2.6 in            

(66 mm) 

0.7 in            

(18 mm) 

* Factory Setting  

Отзывы: