Care and Maintenance
Filters
Dirty filters reduce the air flow and the appliance’s
ability to produce heat. The filters should be
cleaned frequently during the heating season. If
the filters become blocked the filter indicator lamp
will flash red. Eventually the appliance will turn
off and display fault code 14 on the control panel
display.
To clean the filters, the
appliance should be
OFF and cool. Remove
the filter and clean it
using a soft dry cloth or
vacuum. If the filter is
greasy wash with warm
soapy water, rinse, and
dry completely.
Maintenance
Repairs should be performed by a qualified
service technician. The appliance should be
inspected annually by a qualified service
technician. More frequent cleaning may be
required due to excessive lint from carpeting,
bedding material, etc. It is imperative that control
compartments, burners, and circulating air
passage ways of the appliance be kept clean.
Any screen or guard removed for servicing the
appliance must be replaced prior to operating the
appliance. Clean as follows:
1. Turn heat off. Allow to cool for one hour.
2. Remove the front panel by removing six
screws.
3. Use pressurized air to remove dust from the
main burner, heat exchanger, and fan blades.
4. Use soft dry cloth to wipe cabinet.
Do not use wet cloth or spray cleaners on the
burner.
The flue should be inspected annually for
blockages or damage.
Motors are permanently lubricated and do not
need periodic lubrication. Keep fan and motor
free of dust and dirt by cleaning annually.
Verify proper operation after servicing.
Visual Inspection of Flame
Check that the burner flames are operating
normally. The flame can be seen through the
circular window through the louvers.
When operating normally the burner flame should
appear as long, clear, blue, stable, streaks.
Yellow flames or an orange color is abnormal and
maintenance is required.
NORMAL
ABNORMAL
Care of Exterior
Dampen soft cloth with warm water. Wring water
out well and wipe the unit.
Do not use volatile substances such as benzene
or thinners. They cause fading of the paint and
deformation of the resin.
CAUTION
Label all wires prior to disconnection when
servicing controls. Wiring errors can cause
improper and dangerous operation.
Snow Accumulation
Keep the area around flue terminal free of snow
and ice. The appliance will not function properly
if the intake air or exhaust is impeded by
obstructions.
Flame Rod
Yellow flames or
orange color
Long, clear, blue,
stable flames
Flame Rod
AIR FILTERS
Содержание RHFE-201FA
Страница 24: ...24 Rinnai Corporation RHFE 201FA Cut Away Diagram ...
Страница 27: ...27 Rinnai Corporation RHFE 201FA Flow Diagram ...
Страница 28: ...28 Rinnai Corporation RHFE 201FA Parts List For replacement parts call Rinnai at 1 800 621 9419 ...
Страница 29: ...29 Rinnai Corporation RHFE 201FA Parts List ...
Страница 30: ...30 Rinnai Corporation RHFE 201FA Parts List ...
Страница 31: ...31 Rinnai Corporation RHFE 201FA Parts List ...
Страница 32: ...32 Rinnai Corporation RHFE 201FA Parts List ...
Страница 33: ...Parts List 33 Rinnai Corporation RHFE 201FA ...
Страница 34: ...Parts List 34 Rinnai Corporation RHFE 201FA ...
Страница 38: ...38 Rinnai Corporation RHFE 201FA ...
Страница 39: ......