Operation Manual

SAFETY

DO NOT MODIFY THIS APPLIANCE.
Failure to comply with these instructions could result in a fire or explosion, which could cause
serious injury, death or property damage.

Improper installation, adjustments, service or maintenance can cause serious injury, death or
property damage. Such work must be performed by an authorised person.

a. The appliance must be installed in accordance with the local gas and electrical authority 

regulations.

b. For information on gas consumption, refer to the data plate on the appliance.

c. This appliance must not be installed where curtains or other combustible materials could 

come into contact with it. In some cases curtains may need restraining.

d. Heat emanating from the front of this appliance may over time affect the appearance of 

some materials used for flooring such as carpet, vinyl, cork or timber. This effect may be 
amplified if the air in the room contains cooking vapours or cigarette smoke. To avoid this 
possibility, it is recommended that a mat be placed in front of the appliance, extending at 
least 750 mm in front of it. 

e. The appliance is not intended for use by young children or infirm persons without 

supervision.

f.

Young children should be supervised to ensure they do not play with the appliance.

g. If the supply cord is damaged or requires replacing, it must be replaced by the 

manufacturer or the manufacturer's agent or similarly qualified person in order to avoid a 
hazard.

THIS APPLIANCE MUST BE INSTALLED, SERVICED

AND REPAIRED BY AN AUTHORISED PERSON.

The wire mesh guard supplied with this appliance must not be 

permanently removed as it fulfils an operational safety function. 

Additional dress guards including free standing types may be 

used in conjunction with, but not replace, the dress guard 

supplied with this appliance.

WARNING

IMPORTANT

100mm

1000mm

100mm

250mm

The above diagram shows the clearances required

around this heater whilst in operation .

WARNING

WARNING

WARNING

WARNING

Содержание RHFE-1250ETR

Страница 1: ...OH S requirements This appliance must be installed maintained and removed by an Authorised Person For continued safety of this appliance it must be installed and maintained in accordance with the man...

Страница 2: ...R RHFE 1250ETR Flamefire We trust you will have many years of comfort and enjoyment from your appliance BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL...

Страница 3: ...OPERATION WITHOUT THE REMOTE CONTROL AUTOMATIC MODE 10 OPERATION WITH THE REMOTE CONTROL 10 TURNING ON THE POWER 11 USING THE REMOTE CONTROL TO OPERATE THE HEATER 11 FLAME FUNCTION 12 PROGRAMMED HEATE...

Страница 4: ...951ETR RHFE 1250ETR Flamefires are supplied in 3 separate cartons the following tables list which components are in each carton Ensure that the components listed are present before proceeding with the...

Страница 5: ...Dust filter meshing is fixed to the inlets of the room air return 3 ON OFF BUTTON Turns the heater On or Off 7 RECEIVER WINDOW BLOCKAGE INDICATOR Remote control receiver Indicator for filter louvre bl...

Страница 6: ...t Override ExtraLow Time Flame 20 11 21 14 15 16 17 19 18 CONTROL BUTTONS Used to select the temperature flame picture and adjust timers STANDBY ON BUTTON Stops and Operates the heater remotely FLAME...

Страница 7: ...unctions The Dual Timer feature means that you can Set and Forget your heater It will turn itself ON or to STANDBY at the times you have programmed until you cancel the Timer program Pre Heat This fun...

Страница 8: ...be amplified if the air in the room contains cooking vapours or cigarette smoke To avoid this possibility it is recommended that a mat be placed in front of the appliance extending at least 750 mm in...

Страница 9: ...m air discharge louvres and glass must be avoided DO NOT allow young children or the infirm to sleep directly in front of the heater while in operation DO NOT allow anyone to sit on or lean against th...

Страница 10: ...he On Off button on the left hand side of the heater Operation in this manner is known as automatic mode In automatic mode the default set temperature is 22 C For operation in other modes the remote c...

Страница 11: ...teries NEVER mix old and new batteries Remove batteries if the remote control is not going to be used for a long period This will help avoid damage from leaking batteries To replace batteries simply u...

Страница 12: ...show that the flame function is in operation 3 Use the Up and Down buttons to select the desired flame picture The number of bars illuminated correspond to the flame picture setting selected To retur...

Страница 13: ...imers may need to be re programmed Prior to using timers ensure that the desired temperature has been set See ADJUSTING THE TEMPERATURE on page 11 1 One or both Timers can be used While the heater is...

Страница 14: ...r continues to operate with the main burner on low to provide a flame picture with minimal heat output In some cases this may still cause the room to become warmer than desired Extra Low Function ON W...

Страница 15: ...before cleaning filters DO NOT continue to use the heater once this Indicator is flashing When an obstructive build up is detected the Blockage Indicator LED which is located above the Receiver Window...

Страница 16: ...he thermostat operates This is the sound of the solenoid gas valves opening and closing to regulate the gas flow and is normal When the appliance is turned off Convection fan continues to run after tu...

Страница 17: ...ation Should a fault occur the Flamefire will shut down the fault that has caused the shut down will be indicated by a pair of flashing digits in the Error Display window and a RED flashing Operation...

Страница 18: ...CASTING 22 FLUE TERMINAL LOCATION 23 HEATER INSTALLATION 24 1 UNPACKING THE APPLIANCE 24 2 CONNECTING THE FLUE SYSTEM 24 3 SECURING THE ENGINE 25 4 CONNECTING THE APPLIANCE TO THE GAS SUPPLY 25 5 INST...

Страница 19: ...des air for combustion to the appliance and allows expulsion of combustion products to atmosphere Results in room sealed appliance Convection Fan Double drum 160mm x 180mm 3 speed Centrifugal Combusti...

Страница 20: ...nents MUST BE used The Rinnai RHFE 951ETR RHFE 1250ETR units MUST NOT be flued into natural draft flue system or via a chimney Consult the Rinnai Power Flued Flamefire Space Heater Co axial Flue Syste...

Страница 21: ...pplied The power cord passes through the gap at the rear left of the appliance Rinnai recommend the heater be plugged into a 240V 10A earthed power point The power point must be a maximum of 1500 mm t...

Страница 22: ...Kit ASPKIT03 ESPIPE900 ESBEND ESWTKIT Order number of lengths as required Flue is NOT to be terminated under the floor or in a roof space Down Out and vertical through roof flue installations are per...

Страница 23: ...g a terminal 500 500 h From any other flue terminal cowl or combustion air intake 500 300 Appliances up to 150 MJ h input 500 300 Appliances over 150 MJ h input up to 200 MJ h input 1500 300 Appliance...

Страница 24: ...inlet pipe The heater does not come supplied with flue components These are purchased separately ONLY the specified Rinnai flue components MUST be used with this appliance Connections between the hea...

Страница 25: ...ks Use a soapy solution to test all gas connections If a leak is present bubbles will form at the leak point When finished remove any residue with a rag Prevent any soapy solution from coming in conta...

Страница 26: ...pair of pin holes in their bases log has an additional location pin on its top Fit these logs to the back of the burner box as shown 2 Logs each have both a pin hole and a slot in their base and are...

Страница 27: ...in at one end on its top Fit the log to front of the burner box and onto the pin of log as shown 4 Log has both a pin hole and a slot in its base and a location pin midway on its top Fit the log to fr...

Страница 28: ...ar burners MUST NOT exceed 35 seconds If complete ignition exceeds 35 seconds reposition granular media as per step 2 above and re test The stone set for the RHFE 951ETR consists of 30 stones of vario...

Страница 29: ...scia mounting brackets of the heater engine 2 Position the fascia close to the heater engine and connect the RJ45 plug into the socket located on the inside top left of the fascia this connects the pu...

Страница 30: ...___________________________________________________ Serial Number _____________________________________________________________________ Installation Address ___________________________________________...

Страница 31: ...AC 230 240V bl bl r 3 2 1 3 2 1 4 3 2 1 9 8 7 6 5 4 3 2 1 r bk w gy or bl bl r w w bk bk 3 1 4 3 2 1 gr y 1 2 3 4 3 4 1 2 2 1 1 2 1 2 1 2 1 1 3 3 w bk r w bk r bl 1 1 4 4 w bk r bl COM HI MED LOW y r...

Страница 32: ...nai appliance If your appliance requires service please call our National Help Line Rinnai recommends that this appliance be serviced every 2 years Head Office 100 Atlantic Drive Keysborough VIC 3173...

Отзывы: