Earthing Requirement:
The Earthing installation should be carried out in accordance with the local
Wiring Regulations.
Where EARTHING of the premises is not evident, it is
neccessary to run an EARTH CONDUCTOR and solidly connect an earth
rod local to the installation
. The following notes are for guidance only:
1.2.1 Select a damp place to bury the earth rod.
1.2.2 Connect earth conductor of minimum 2.5mm² (7/0.67mm) to the appliances
Earth ( ) terminal. Connect other end of the earth conductor to the earth rod.
1.2.3 Check to ensure earthing resistance is less th
an 100Ω. It may be neccessary
to drive two or more rods and connect them together to achieve a
satisfactory results.
1.2.4 Installation of earth rod must be carried out by
a registered and certified wiring
contractor.
Ground surface
To Ea
rth C
onne
ction poi
nt
To Ear
th Conne
ction poi
nt
To Ear
th Conne
ction poi
nt
Earth Rod
Ground surface
Ground surface
at least 1m
About 2m
THIS APPLIANCE MUST BE EARTHED, TO MAKE SURE EARTH
WIRE AND HEATER UNIT HAVE PROPER GROUNDING IN HOUSEHOLD.