ELECTRICAL SUPPLY
GPO (General Purpose Outlet)
Where a power point is used it
MUST
be 230 V, rated at 10A and
MUST
be
earthed. This power point
MUST NOT
be located above the heater. Alternatively
the appliance can be direct wired if the power supply is to be concealed.
The heater engine is fitted with a 1.5 m power cord and three pin plug
(7a)
which
exits the appliance from the rear panel at the lower left.
Direct Wired Installations
Alternatively the appliance can be direct wired if so required.
IMPORTANT
A qualified electrician will need to be consulted where a direct
wired installation is required.
Any such installation
MUST
comply with the requirements
of AS/NZS 5601, AS/NZS 3000 and any other relevant local
regulations.
7a
SUPPLY CONNECTIONS