Fire Prevention Equipment in Surrounding Area
• Allow sufficient space between the equipment
and flammable objects such as furniture, walls
and shelves.
– Allow at least the standard installation dimensions
(in figure at right) in consideration of maintenance
management and works. Failure to do so might result
in fire or the equipment overheating and cause burns.
300
250
500
45
100
Standard installation dimensions
(Unit: mm)
Checking gas and power supply used
• Use the equipment with only the gas type (gas
group) and power supply (power voltage/frequency)
indicated on the data plate on the
equipment. Do not use with other
gas types or power supplies.
– Do not use the equipment when gas and
power supply used does not match the
gas and power supply indicated on the
data plate. Then, incomplete combustion
may cause carbon monoxide poisoning,
or cause explosive ignition or equipment
to malfunction.
Data plate (example)
MODEL
FOR
GAS
PRESSURE
IN.W.G
INPUT Btu/hr
VOLTAGE V
CYCLE Hz
SERIAL NO.
RINNAI CORPORATION MADE IN JAPAN
Model Name
Product date (year/month)
Lower 2 digits of production year
Production month indicated at 2 digits
Check gas type
Safety Precautions
(Installation)
Warning
This symbol indicates that ignoring the accompanying explanation and mishandling
the product might result in death or serious injury or might cause the risk of fire.
Remodeling/Disassembly Prohibited
• Users must never use tools to install, move, disassemble,
repair, or remodel the equipments themselves.
– Doing so may cause carbon monoxide poisoning or fire, and cause
the equipment to malfunction.
– Installation, moving, disassembly, repair, or remodeling of the
equipment requires highly special knowledge.
Disassembly
Prohibited