48
Display
For displays marked by *, the buzzer
does not sound.
Safety Interlock
Function
Cause
Remedy
Reference
Page
<blinks>
Drum rotation sensor
(drum rotation abnormality)
Gas supply is stopped and cool operation is
automatically started when the drum does not rotate
or drum rotation is insufficient.
There is too much washing loaded in the equipment.
Reduce the amount of washing, and perform operation again. (as a
guideline after spin drying, within 9 kg)
26, 37
The electrical circuit of a motor, etc. is malfunctioning.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
<blinks>
Fan rotation sensor
(discharge fan rotation
abnormality)
Gas supply is stopped and cool operation is
automatically started when the discharge fan does
not rotate, drum rotation is insufficient or the drum
rotates abnormally.
Thin clothes with poor permeability or a mat is
covering the lint filter.
Remove the clothes with poor permeability or the mat, then perform
operation again.
24
The discharge tube is blocked.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
The electrical circuit of a motor, etc. is malfunctioning.
<blinks>
Ignition/light out safety interlock
(ignition failure for 5 times
continuous)
Gas supply is stopped and cool operation is
automatically started when lighting of the pilot light
fails (continuously for 5 times) during ignition.
This occurs, for example, when the gas cock is
closed or was not completely open.
Wait approximately 2 minutes for cool operation (replacement with
fresh air) to end before inspecting and performing operation again.
23
<blinks>
Error can be
canceled
Drum rotation sensor
(drum rotation abnormality)
Gas supply and operation are stopped when the
drum does not rotate or drum rotation is insufficient.
There is too much washing loaded in the equipment.
Reduce the amount of washing, and perform operation again. (as a
guideline after spin drying, within 9 kg)
26, 37
Error cannot
be canceled
Fan rotation sensor
(discharge fan rotation
abnormality)
The electrical circuit of a motor, etc. is malfunctioning.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
<blinks>
Overheat prevention device
(thermocouple)
Gas supply is stopped and cool operation is
automatically started when lint blocks the lint filter
or when the inside of the equipment overheats
abnormally.
This occurs when there is insufficient air for
combustion.
Wait approximately 35 minutes for cool operation to end before
inspecting and performing operation again. (When there is too much
washing loaded in the equipment, remove the clothing or remove
clothing with poor permeability, then perform operation again.)
24, 26,
40 to 42
Lint has accumulated on the lint filter or the lint filter
is blocked with lint.
Thin clothing with poor permeability is covering the
lint filter.
There is too much washing loaded in the equipment.
This occurs when dust has built up inside of the
equipment.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
The discharge tube is blocked.
<out>
*
Overheat prevention device
(temperature fuse)
Gas supply, operation are stopped when the inside
of the equipment overheats abnormally.
This occurs when there is insufficient air for
combustion.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
24, 26,
40 to 42
Lint has accumulated on the lint filter or the lint filter
is blocked with lint.
Thin clothing with poor permeability is covering the
lint filter.
There is too much washing loaded in the equipment.
The discharge tube is blocked.
Repair is necessary. Contact the store of purchase or call Customer
Services Hotline.
-
Overcurrent prevention device
(current fuse)
The current fuse and gas supply and operation are
stopped when an overcurrent flows.
This occurs when an electrical circuit short-circuits.
Display other than the above
Safety interlocks other than the
above
A safe shutdown occurs when an abnormality
other than the above occurs.
Wait for the equipment to stop automatically before performing operation again. Repair is required when the safety interlock
operates again. Contact the store of purchase or call Customer Services Hotline.
-