Rinnai RB-27f Скачать руководство пользователя страница 11

1. Please block gas pipe (such as entrance to pipe connector) to prevent blockage

caused by foreign matter.

2. Clear away all residues, and cover with plastic bag to prevent dust and foreign

matter from entering.

3. Pack into box and store in a dry location.

If product is dismantled, please reassemble cor rectly
after maintenance.

8. Easy repair

*If failure occurs, please refer to easy repair chart.

Not using built in hob for a long time

Problem

Cause

Remedy

Turn off stove,then open gas
tank

Replace gas tank

Repeat ignition until
successful

Adjust gas pressure

Air in rubber piping

Inappropriate gas

pressure

Too low

Too high

Rubber piping bent

Electrode dirty

Fire vent or air vent blocked

Burner head and pan support
installed incorrectly

Ignition operation incorrect

Air regulation incorrect

Switch knob stuck

Ignition high tension cable
not connected

Incorrect gas type

Inappropriate ignition
operation

Ignition device failure

Safety device
(thermocouple) actuation

Straighten piping

Wipe clean with dry cloth,
clear away residue (or wipe
off water drops)

Install Correctly

Operate correctly

Adjust air amount correctly

Check and adjust

Connect high tension cord
to electrode

See “ignition operation” or
press longer on swith knob

Check and fix/replace

Check and amend

Safety device

(thermocouple) failure

Gas not turned on or
insufficient gas

LPG almost used up

U

n

a

b

leo
r

d

iff

ic

u

ltt

oi
g

n

it

e

L

e

a

df
ir

ed

o

e

s

n

o

tg
oo

u

t

D

iff

ic

u

ltt

ol
ig

h

t

fir

e

E

x

p

lo

s

iv

ef
la

m

e

O

ra

n

g

e

-y

e

llo

w

fla

m

e

U

n

s

ta

b

lef
la

m

e

A

b

n

o

rm

a

ln
o

is

e

F

la

m

e

sg
oo

u

t

d

u

ri

n

gu

s

e

F

la

m

e

sg
oo

u

tw
h

e

n

h

a

n

d

sr
e

le

a

s

e

s

w

it

c

hk
n

o

b

If problem can not be solved, please contact our ser vice center
immediately.

Содержание RB-27f

Страница 1: ...lation e Installation site a Ignition operation b Flame out operation c Governor function a Special notes b Ventilation notes c Fire prevention d Gas leak prevention and countermeasures For domestic u...

Страница 2: ...when used with high gas pressure Gas type Description Tanked LP gas Standard gas pressure 1 Glass top plate series Illustration for reference only The actual item may vary 1 Top plate 2 Switch knob 3...

Страница 3: ...2 Stainless steel top plate series 5 8 4 6 7 2 3 2 4 6 1 5 7 5 7 4 6 1 3 2 3 1...

Страница 4: ...istance to high heat 8 Quick ignition quick ignition device installed to shorten ignition time 4 Installation notes In case installation site consists of flammable materials such as wood or plastic 1...

Страница 5: ...m 7 4 Place burner ring cover burner support switch knob accordingly into correct position 5 Battery install from bottom of main body Battery must be installed correctly to enable ignition discharge b...

Страница 6: ...sten with fixing ring 5 Leakage test apply neutral detergent soap water onto connector turn on the gas If bubbles appear it means there is leakage Testing with tinder is strictly forbidden 6 Do not sh...

Страница 7: ...onding flame level you need b Flame out operation 2 After use remember to cut off the gas to prevent gas leakage and fire breakouts To put out the flame turn knob clockwise back to position as shown i...

Страница 8: ...5 Diameter of cookware must not exceed 28 cm weight of cookware must not exceed 15kg or failures may occur 6 Do not bash surface of gas stove This may cause top plate to deform and fracture b Ventila...

Страница 9: ...s leakage 5 After use or before going to bed check gas and gas tank are properly turned off 6 In case of gas leakage stop using immediately turn off gas and open windows to allow air circulation Conta...

Страница 10: ...neutral detergent then wipe with dry cloth Burner head maintenance If fire vent is blocked by oil residue or flames are abnormal scrub burner head with copper brush and rinse with water Thenwipe dry...

Страница 11: ...incorrectly Ignition operation incorrect Air regulation incorrect Switch knob stuck Ignition high tension cable not connected Incorrect gas type Inappropriate ignition operation Ignition device failur...