background image

Rinnai

6

PEPH_OIM

SAFETY & IMPORTANT POINTS

UNPACKING THE APPLIANCE

If any damage is evident 

DO NOT INSTALL 

or 

OPERATE

 and contact your supplier for advice. 

WHAT’S IN THE BOX

The package should contain: 

Heater fitted with flexible cord and plug.
A plastic bag containing the Operating and Installation Instructions and wall mounting screws.
Two plastic bags containing four castors, two castor brackets, screwdriver and four screws.

SAFETY

It is important the following precautions are followed to minimise the risk of overheating, fire, electric shock and
injury. 

• The heater is fitted with an Australian flexible cord and 2 pin plug intended for connection to an

Australian 10 Amp socket outlet. It is not suitable for connection in other countries or alternative
power supplies. Ensure that the voltage and frequency of the power supply correspond to the
ratings on the dataplate of the appliance.

• This heater must not be located immediately below or directly in front of a socket-outlet.

• The heater may be direct wired only by a licensed electrical trades person in accordance with

local regulations.

• This heater is not intended for use by persons (including children) with reduced physical,

sensory or mental capabilities, or lack of experience and knowledge, unless they have been
given supervision or instruction concerning use of the appliance by a person responsible for
their safety.

• Young children should be supervised to ensure they do not play with the appliance.

• DO NOT allow children or persons with reduced physical, sensory or mental capabilities to sleep

directly in front of the heater.

• DO NOT allow children to ‘post articles’ into the louvres of the heater.

• The electrical cord must not come into contact with the heated parts of the heater.

• DO NOT use power boards or double adaptors with this heater.

• DO NOT coil or bundle the electric cord to reduce it’s length as overheating of the cord may occur

which could result in a fire hazard.

• The flexible cord and plug must not be modified. If the cord or plug are damaged, they must be

replaced by Rinnai or a Rinnai appointed service agent.

• DO NOT cover or place articles on or against any parts of this heater, to avoid overheating.

• DO NOT sit on this heater.

• If used as a portable heater, do not use in the immediate surroundings of a bath, a shower or a

swimming pool.

• If used as a portable heater, unplug and allow to cool before placing in storage.

• If used as a portable heater, do not move whilst it is turned on.

• DO NOT unplug the heater by pulling on the flexible cord.

• DO NOT handle any parts of the heater, including the plug and flexible cord, with wet or damp

hands.

• DO NOT immerse the appliance, flexible cord and plug in water or any other liquid.

• DO NOT place containers of any liquid or wax on top of the heater.

• Turn off the appliance and unplug from the power socket outlet when not in use.

• DO NOT use in areas where flammable liquids are stored.

• This appliance is suitable for indoor use only.

• Never dismantle the appliance. Tampering with electrical connections and components is highly

dangerous and may cause appliance malfunction.

IMPORTANT

Содержание PEPH-10PEW

Страница 1: ...d installed and maintained in accordance with these instructions Read these instructions thoroughly before attempting installation and operation Keep these instructions handy for future reference Operation Installation Manual Electric Panel Heaters Models PEPH 10PEW PEPH 15PEW PEPH 22PEW ...

Страница 2: ...PEPH_OIM BEFORE PROCEEDING WITH THE OPERATION OR INSTALLATION OF YOUR NEW HEATER PLEASE READ THIS MANUAL THOROUGHLY AND GAIN A FULL UNDERSTANDING OF THE REQUIREMENTS FEATURES AND OPERATION OF YOUR NEW APPLIANCE ...

Страница 3: ...L OPERATION 8 PROGRAMMED OPERATION 9 Setting The Clock 9 Setting The Programmed Operation Timer 10 24 Hour Reset Button 11 ANTI FROST PROTECTION FUNCTION 11 ELECTRONIC LOCK FUNCTION 11 To Activate The Lock 11 To Deactivate The Lock 11 CARE AND MAINTENANCE 12 CARE OF THE HEATER 12 SERVICE AND REPAIR 12 DISPOSAL 12 INSTALLATION 13 GENERAL 13 WALL INSTALLATION 13 FREESTANDING INSTALLATION 14 CONTACT ...

Страница 4: ...Rinnai 4 PEPH_OIM This page is intentionally blank ...

Страница 5: ...d out by persons other than Rinnai service persons or service agents 5 Where it is found that there is no fault with the appliance and the issue is related to the installation or is due to the failure of electricity supply FEATURES This heater incorporates the following design features DIY Installation This heater is suitable for Do It Yourself installation Silent Operation Electric element operat...

Страница 6: ... the appliance DO NOT allow children or persons with reduced physical sensory or mental capabilities to sleep directly in front of the heater DO NOT allow children to post articles into the louvres of the heater The electrical cord must not come into contact with the heated parts of the heater DO NOT use power boards or double adaptors with this heater DO NOT coil or bundle the electric cord to re...

Страница 7: ...button Clock Temperature display Lock indicator Heater operation indicator Red Timer operation indicator Warm air discharge 240 Volt power cord plug Air inlets Optional castors for floor mounting see INSTALLATION on page 14 for installation options Mounting bracket for wall installation see INSTALLATION on pages 13 14 for installation options 17 14 15 16 A 13 1 B A 2 5 7 4 6 8 3 10 12 9 11 A B 1 2...

Страница 8: ...rature will now be set and displayed alternately with the time display see Setting The Clock on page 9 If the selected temperature is above that of the current room temperature the red operation indicator will illuminate and the heater will begin to heat the room If the selected temperature is less than that of the current room temperature the red operation indicator will go out and the heater wil...

Страница 9: ...been set press the TIME button to set the minutes and use the Up or Down buttons to set the minutes 2 Once the minutes are set press the time button to save the set time The time displayed is in 24 Hour time Before the PROGRAMMED OPERATION can be used the clock will need to be set If the clock is not set when the heater is turned on the time will default to 00 00 12 Midnight and will begin running...

Страница 10: ...ings press the PROG button 6 To stop Timer operation press the POWER button If after 60 seconds no buttons are pressed the heater will revert back to the current operating setting Simply press the PROG button to re enter the timer setting operation If the appliance is turned off using the power button the timer settings will be saved If the appliance is turned off using the main power switch then ...

Страница 11: ...l below 5 C ELECTRONIC LOCK FUNCTION The Lock function is designed to prevent accidental operations and small children from altering the heater settings To Activate The Lock Press the Up or Down buttons simultaneously until three beeps are heard and the padlock symbol is displayed All control functions are now locked and none of the buttons on the control will work To Deactivate The Lock To deacti...

Страница 12: ...ld detergent such as dishwashing liquid if required 5 Ensure the heater is dry before reconnecting to the electricity supply SERVICE AND REPAIR If the electric power cord or plug are damaged they must be replaced by Rinnai or a Rinnai appointed service agent There are no user serviceable parts inside the appliance All service and repair work must be carried out by persons competent and permitted b...

Страница 13: ... mounting bracket depressing both to detach the mounting bracket from the back of the panel heater 3 Position the mounting bracket on the wall Ensure the two bottom mount holes are at least 175mm from the floor and drill holes as required This heater MUST NOT be located immediately below a socket outlet This heater MUST be positioned within one metre of a socket outlet to ensure the flexible cord ...

Страница 14: ...with the back of the heater facing you 3 Assemble the 2 castors to the each castor bracket by pushing the metal shaft fully home 4 With the front end of the castor support bracket pointed towards the front of the heater align the four locating tabs with the four of the outer most air inlets then push down and forward until the tabs are fully engaged with the heater Then secure each of the castor b...

Страница 15: ...Rinnai 15 PEPH_OIM NOTES ...

Страница 16: ...rvice please call our National Help Line Head Office 100 Atlantic Drive Keysborough VIC 3173 P O Box 460 Braeside Victoria 3195 Product Sales and Service National Phone 1300 555 545 Fax 1300 555 565 Technical Helpline and Spare Parts National Mon Fri 8am 5 30pm EST Phone 1300 555 545 Fax 1300 300 141 Cost of a local call higher from mobile or public phones E mail enquiry rinnai com au For further ...