Infinity REU-3203W
- 46 -
©Rinnai
d. Remove transformer installation bracket screw.
8)
Removal of the
Gas Inlet, Solenoid, Flame Rod
a. Remove front panel (4 screws). (Refer Item 1.)
b. Remove five (5) combustion screws located on
outer edge of manifold plate.
c. Remove two high tension leads from spark
ignitors. Unplug wiring from solenoid coils.
d. Remove two (2) manifold and gas control screws
and take out by hand.
e. Remove damper (3 screws).
f. Remove two (2) burner retaining screws, then
remove combustion chamber front panel (9
screws).
g. Take out the burner unit.
9)
Removal of the
Gas Control
a. Remove front panel (4 screws). (Refer Item 1.)
b. Remove the manifold. Refer to section 8) a. to d.
c. Remove four (4) screws on gas connection inlet
and gas control (assy), and pull out the gas
connection. Handle O-ring carefully.
d. Remove one (1) gas control (assy) screw and pull
out gas control (assy).
Содержание INFINITY REU-3203W
Страница 1: ...INFINITY REU 3203W Infinity High Capacity Continuous Flow Gas Hot Water System SERVICE MANUAL...
Страница 12: ...Infinity REU 3203W 7 Rinnai 4 Dimensions A Gas 41 Cold Water 51 Hot Water 42 Power 27...
Страница 16: ...Infinity REU 3203W 11 Rinnai 7 Cutaway Diagram...
Страница 53: ...Infinity REU 3203W 48 Rinnai Heat Exchanger Back d Remove one 1 screw of the bi metal overheat switch...
Страница 54: ...Infinity REU 3203W 49 Rinnai 21 Exploded Diagram...
Страница 55: ...Infinity REU 3203W 50 Rinnai...
Страница 56: ...Infinity REU 3203W 51 Rinnai...
Страница 57: ...Infinity REU 3203W 52 Rinnai...
Страница 61: ...Infinity REU 3203W Rinnai Notes...
Страница 62: ...Infinity REU 3203W Rinnai...
Страница 63: ...Infinity REU 3203W Rinnai...