Infinity REU-3203W
- 40 -
©Rinnai
11) Adjust the regulator screw on the modulating valve as
required to the pressure below. (fig 4)
12) Lock the regulating screw on the modulating valve.
Pressure Setting low
N.G.
0.18 kPa
Prop. G
0.35 kPa
LPG
0.35 kPa
13) Set the Infinity to 'Forced High' combustion by setting
both No. 2 and No. 3 dipswitches of the bottom (SW2)
set to 'ON'. (fig 5) Ensure maximum water flow.
14) Check the burner test point pressure.
15) Adjust the high pressure Potentiometer (POT) on the
Printed Circuit Board (PCB). As required to the
pressure shown.
Pressure Setting high
N.G.
0.74 kPa
Prop. G
1.76 kPa
LPG
1.76 kPa
16)
IMPORTANT
: Set dip switches No's 2 and 3 on the
bottom (SW2) set of switches to 'OFF' to return the
appliance to 'Normal' combustion.
17) Close hot water tap.
18) Turn OFF the gas supply and 240V power supply.
19) Remove pressure gauge, and replace sealing screw.
20) Turn 'ON' the gas supply and 240V power supply.
21) Operate unit and check for gas leaks at test point.
22) Replace the front cover of the appliance.
Warning
DURING PRESSURE TESTING OF THE INSTALATION ENSURE
GAS COCK SITUATED BEFORE UNIT IS SHUT OFF.
fAILURE TO DO SO MAY RESULT IN SERIOUS DAMAGE TO
THE APPLIANCE AND POSSIBLE INJURY.
Содержание INFINITY REU-3203W
Страница 1: ...INFINITY REU 3203W Infinity High Capacity Continuous Flow Gas Hot Water System SERVICE MANUAL...
Страница 12: ...Infinity REU 3203W 7 Rinnai 4 Dimensions A Gas 41 Cold Water 51 Hot Water 42 Power 27...
Страница 16: ...Infinity REU 3203W 11 Rinnai 7 Cutaway Diagram...
Страница 53: ...Infinity REU 3203W 48 Rinnai Heat Exchanger Back d Remove one 1 screw of the bi metal overheat switch...
Страница 54: ...Infinity REU 3203W 49 Rinnai 21 Exploded Diagram...
Страница 55: ...Infinity REU 3203W 50 Rinnai...
Страница 56: ...Infinity REU 3203W 51 Rinnai...
Страница 57: ...Infinity REU 3203W 52 Rinnai...
Страница 61: ...Infinity REU 3203W Rinnai Notes...
Страница 62: ...Infinity REU 3203W Rinnai...
Страница 63: ...Infinity REU 3203W Rinnai...