Infinity REU-3203W
- 28 -
©Rinnai
3d.Solenoid Valve 3 (SV
3
) Circuit.
a.)
Disconnect Solenoid connector, measure
resistance between Yellow and Black.
Normal:
1.8~2.2k
Ω
If normal, proceed to
b
.
Faulty:
Replace Solenoid Valve 3.
b.)
Measure voltage between Yellow and
Black of SV
3
connector.
Normal:
DC80~100V
If normal, proceed to Modulating valve
circuit.
Faulty:
Replace PCB.
3e.Modulating Valve Circuit.
a.)
Disconnect Modulating Valve fasten
terminal and measure resistance between
terminals.
Normal:
70~90
Ω
If normal, proceed to
b
.
Faulty:
Replace Modulating Valve.
b.)
Measure voltage between Orange and
Orange of Modulating Valve fasten
terminal.
Normal:
DC1.0~25V
If normal, proceed to
c
.
Faulty:
Replace PCB.
c.)
Check the gas secondary pressure change
when set temperature on the remote
control changes from 37 to 55
o
C.
Normal:
If secondary pressure changes,
go to Water Flow Servo Circuit.
Faulty:
Replace Modulating Valve.
Содержание INFINITY REU-3203W
Страница 1: ...INFINITY REU 3203W Infinity High Capacity Continuous Flow Gas Hot Water System SERVICE MANUAL...
Страница 12: ...Infinity REU 3203W 7 Rinnai 4 Dimensions A Gas 41 Cold Water 51 Hot Water 42 Power 27...
Страница 16: ...Infinity REU 3203W 11 Rinnai 7 Cutaway Diagram...
Страница 53: ...Infinity REU 3203W 48 Rinnai Heat Exchanger Back d Remove one 1 screw of the bi metal overheat switch...
Страница 54: ...Infinity REU 3203W 49 Rinnai 21 Exploded Diagram...
Страница 55: ...Infinity REU 3203W 50 Rinnai...
Страница 56: ...Infinity REU 3203W 51 Rinnai...
Страница 57: ...Infinity REU 3203W 52 Rinnai...
Страница 61: ...Infinity REU 3203W Rinnai Notes...
Страница 62: ...Infinity REU 3203W Rinnai...
Страница 63: ...Infinity REU 3203W Rinnai...