Infinity REU-V3232W /HD250E REU-V3232WC
- 35 -
Issue 1 - 8/09/03 ©Rinnai
17.Anti-frost Heater Circuit
a.)
Disconnect relay connectors ( J
4
) and (J
5
)
and measure resistance between White and
WhiteW on heater side (water flow servo and
HW connection).
Normal:
408
Ω
If normal, proceed to
b
.
Faulty:
Replace Valve Heater.
b.)
Disconnect relay connector (J
4
) and (J
5
) and
measure resistance between Yellow and
Yellow on each conector on heater side.
Normal:
653
Ω
If normal, proceed to c.
Faulty:
Replace Anti-frost Heater B (assy).