11.Hot Water Outlet Thermistor Circuit
Check Hot Water Thermistor if error code
32 is displayed.
Disconnect relay connector (E
1
) and measure
resistance White -White.
When disconnected
: resistance >1M
Ω
When short circuit:
resitance > 1
Ω
Normal:
Check Heat exchanger outlet
thermistor
Faulty:
Replace hot water outlet
thermistor.
If normal proceed to Flame Rod circuit.
Faulty:
Replace the Hot water Outlet
Thermistor.
Note:
For controller readout of thermistor
temperature whilst operational refer
maintenance monitor (chapter 17) No. 2.
Disconnect relay connector (E
1
) and measure
resistance White -White.
12.Electrical Fuse
Check the fuse.
a.) Unplug the power plug.
b.) Check whether or not the fuse (3A) x 2 has
blown by measuring the resistance.
Normal:
<1
Ω
If normal go to step Electrical Fuse 13.
Faulty:
Replace fuse/s (3Ax2). Check for a
short next time it’s turned off.
Normal
Temp.
15
o
C
30
o
C
45
o
C
75
o
C
Resistance
12.3 k
Ω
7.0 k
Ω
4.1 k
Ω
1.6 k
Ω
Содержание HD250E REU-V3232WC
Страница 12: ...Infinity REU V3232W HD250E REU V3232WC 7 Issue 1 8 09 03 Rinnai 4 Dimensions...
Страница 18: ...Infinity REU V3232W HD250E REU V3232WC 13 Issue 1 8 09 03 Rinnai 7 Cutaway Diagram...
Страница 24: ...Infinity REU V3232W HD250E REU V3232WC 19 Issue 1 8 09 03 Rinnai 12 Wiring Diagram...
Страница 54: ...Infinity REU V3232W HD250E REU V3232WC 49 Issue 1 8 09 03 Rinnai 21 Exploded Diagram...
Страница 55: ...Infinity REU V3232W HD250E REU V3232WC 50 Issue 1 8 09 03 Rinnai...
Страница 56: ...Infinity REU V3232W HD250E REU V3232WC 51 Issue 1 8 09 03 Rinnai...
Страница 57: ...Infinity REU V3232W HD250E REU V3232WC 52 Issue 1 8 09 03 Rinnai...
Страница 61: ...Infinity REU V3232W HD250E REU V3232WC 56 Issue 1 8 09 03 Rinnai Notes...