8
•
Heat Exchanger Thermistor
: Measures hot water temperature at heat exchanger outlet. If
water temperature reaches a predetermined limit, gas supply is stopped.
•
Hot Water Delivery Thermistor
: Measures hot water temperature at the outlet valve (i.e. the
‘mixed’ temperature).
•
Flame Rod
: Monitors combustion characteristics inside the combustion chamber. If the flame
fails, gas supply is stopped.
•
Overheat Switch
: Situated on the heat exchanger, gas supply is stopped when water
temperature reaches 97ºC for a number of seconds.
•
Fusible Link
: Situated on the heat exchanger, electrical power supply is stopped if the
temperature exceeds 150ºC.
•
Water Pressure Relief Valve
: Safeguards the water circuit against excessive inlet pressure.
Opens at 15 bar, closes at 12 bar.
•
Electrical Fuse
: (3A glass fuse) prevents against over-current. Surge Protector: prevents
against over-current.
•
Boil Dry Prevention
: If water flow sensor detects no flow, gas supply is stopped.
•
Combustion Fan Speed Sensor
: In case of combustion fan defect (no rotation of fan) gas
supply is stopped.
•
Temperature Cutout
: If the delivered hot water temperature rises above the required delivery
temperature for a number of seconds, the gas supply is stopped.
Sensors and Safety Devices
Combustion Specifications
The secondary gas pressure is set with the cover off the unit and a manometer measuring
the pressure from the gas valve (regulator) test point
Gas Type
Injector
size
(mm)
Primary
Pressure (mbar)
Secondary Pressure
(mbar)
Gas Input [Gross]
(kW)
Low High Low
High
Natural Gas
(G20)
1.3 20
1.8
9.0
4.7
34.9
Propane (G31)
37
2.2
14.2
4.9
36.5
Damper
Nat Gas
LPG
Содержание FUA-E
Страница 1: ......
Страница 5: ...5 Glossary of Terms and Symbols ...
Страница 9: ...9 Dimensions ...
Страница 11: ...11 Structure Diagram ...
Страница 17: ...17 Gas Conversion Procedure ...
Страница 18: ...18 Gas Conversion Procedure ...
Страница 25: ...25 Operational Flow Chart ...
Страница 26: ...26 Time Charts ...
Страница 39: ...39 Diagnostic Checks Fault Finding Chart ...
Страница 40: ...40 Fault Finding Chart ...
Страница 41: ...41 Fault Finding Chart ...
Страница 42: ...42 Fault Finding Chart ...
Страница 43: ...43 Fault Finding Chart ...
Страница 44: ...44 Fault Finding Chart ...
Страница 45: ...45 Fault Finding Chart ...
Страница 46: ...46 Wiring Diagram ...
Страница 49: ...49 Dismantling for Service ...
Страница 50: ...50 Dismantling for Service ...
Страница 51: ...51 Dismantling for Service ...
Страница 52: ...52 Dismantling for Service ...
Страница 53: ...53 Dismantling for Service ...
Страница 54: ...54 Dismantling for Service ...
Страница 55: ...55 Dismantling for Service ...
Страница 56: ...56 Exploded Diagram ...
Страница 57: ...57 Exploded Diagram ...
Страница 58: ...58 Exploded Diagram ...
Страница 59: ...59 Exploded Diagram ...
Страница 60: ...60 Exploded Diagram ...
Страница 61: ...61 Parts List ...
Страница 62: ...62 Parts List ...
Страница 63: ...63 Parts List ...
Страница 64: ...64 Parts List ...
Страница 65: ...65 Letter of Compliance ...
Страница 66: ...66 CE Certificate ...
Страница 67: ......