Rinnai Corporation EX17C / EX22C Manual
21
Drilling
Flue
Hole
Ensure that there are no gas or water lines, or
electrical circuits in the wall location where the flue
hole is to be drilled.
Drill the flue hole using a 3 1/8 inch (80 mm) drill.
The center of the hole must be located anywhere
within the shaded area, unless extension kits are
used. See diagram.
For weatherboard walls, drill through the center of
the weatherboard from the outside first and then
through the plasterboard. A template is provided.
For installation without using extension kits, the
configuration of the flue manifold, air intake hose,
and exhaust slide pipe should be as shown when
installation is completed. The shaded area shows
where the flue manifold can be located.
Configuration viewed from behind the appliance.
Flue Hole
3 1/
8"
(8
0
mm)
Use a template (included) to
determine allowable location of the
flue hole.
NOTICE
Содержание Energysaver EX17C
Страница 31: ...Rinnai Corporation EX17C EX22C Manual 31 Cut Away Diagram ...
Страница 34: ...34 Rinnai Corporation EX17C EX22C Manual Parts List For replacement parts call Rinnai at 1 800 621 9419 ...
Страница 35: ...Rinnai Corporation EX17C EX22C Manual 35 Parts List ...
Страница 36: ...36 Rinnai Corporation EX17C EX22C Manual Parts List ...
Страница 37: ...Rinnai Corporation EX17C EX22C Manual 37 Parts List ...
Страница 38: ...38 Rinnai Corporation EX17C EX22C Manual Parts List ...
Страница 39: ...Rinnai Corporation EX17C EX22C Manual 39 Parts List ...
Страница 81: ...Rinnai Corporation EX17C EX22C Manual 81 Notes ...
Страница 82: ...82 Rinnai Corporation EX17C EX22C Manual Notes ...
Страница 83: ...Rinnai Corporation EX17C EX22C Manual 83 Notes ...
Страница 84: ...RHF559 1232X01 00 Printed in Japan 2010 06 ...