background image

107273-UUM-C-0306

USER’S INFORMATION,

MAINTENANCE AND 

SERVICE MANUAL

HIGH EFFICIENCY SEALED COMBUSTION 

DRUM HEAT EXCHANGER SERIES

MODEL: DFAA/DFAH 

(Oil and Gas Conversion Burner/ 

Single Stage Downflow Only)

EFFICIENCY
RATING
CERTIFIED

ISO 9001

Certified Quality

Management System

For Installation In:

1.

Manufactured (Mobile) Homes

2.

Recreational Vehicles & Park Models

3.

Modular Homes & Buildings

The manufacturer recommends that the user read all sec-
tions of this manual and keep the manual for future refer-
ence.

SECTION I: OIL-FIRED FURNACE

FOR YOUR SAFETY 

1.

The furnace area must be kept clear and free of combustible mate-
rials, gasoline and other flammable vapors and liquids.

2.

Insulating materials may be combustible. The furnace must be
kept free and clear of insulating materials. The furnace area must
be examined when installed in an attic or other insulated space or
when insulation is added to be sure that the insulation material has
been kept away from the furnace.

3.

Follow the instructions exactly as shown on the OPERATING
INSTRUCTION LABEL or the Start-up and Shutdown Instructions
on Page 4 of this manual when lighting the furnace or turning the
furnace off.

4.

Should the oil supply fail to shut off or if overheating occurs, shut
off the fuel pump manual valve to the furnace before shutting off
the electrical supply.

5.

Do not use this furnace if any part has been under water. A flood-
damaged furnace is extremely dangerous. Attempts to use the fur-
nace can result in fire or explosion. A qualified service agency
should be contacted to inspect the furnace and replace all oil con-
trols, control system parts, electrical parts that have been wet or
the furnace if deemed necessary.

6.

NEVER

Store flammable materials of any kind near your fur-

nace. Gasoline, solvents, and other volatile liquids should be
stored only in approved containers outside your home. These
materials vaporize easily and are extremely dangerous.

FIRE OR EXPLOSION HAZARD - Failure to follow safety
warnings exactly could result in serious injury, death, or prop-
erty damage.

— 

Do not store or use gasoline or other flammable

vapors and liquids in the vicinity of this or any other
appliance.

—  

WHAT TO DO IF YOU SMELL FUEL OIL:

• Do not try to light any appliance.
• Turn off the electric switch.
• Immediately call your service technician. DO NOT start

the furnace.

• If the control reset button has been pushed more than

one time, the chamber may be flooded with oil. Turn off
the power to the furnace.

— 

 Installation and service must be performed by a qualified 

installer, service agency or the fuel supplier.

TABLE OF CONTENTS

OIL-FIRED FURNACE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1

FOR YOUR SAFETY   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  1
CONTACT INFORMATION FOR USA  . . . . . . . . . . . . . . . . . . . . . . . . . .  1
CONTACT INFORMATION FOR CANADA   . . . . . . . . . . . . . . . . . . . . . .  1
HOW YOUR OIL-FIRED FURNACE WORKS   . . . . . . . . . . . . . . . . . . . .  2
INSTRUCTIONS FOR EXAMINING THE FURNACE . . . . . . . . . . . . . . .  2
OWNER SERVICE AND MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . .  3
START-UP AND SHUTDOWN INSTRUCTIONS  . . . . . . . . . . . . . . . . . .  3
FURNACE USER MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  4

SERVICE AND MAINTENANCE MANUAL . . . . . . . . . . . . . . . . . . . . . . . .  5

SAFETY SECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
SERVICE AND MAINTAIN BURNER  . . . . . . . . . . . . . . . . . . . . . . . . . . .  5
FURNACE MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
FURNACE CLEANING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  6
REPLACING THE OIL PUMP  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  7
OIL FURNACE SEQUENCE OF OPERATION . . . . . . . . . . . . . . . . . . . .  8
TYPICAL PRIMARY CONTROL SEQUENCE OF OPERATION  . . . . . .  8
START UP AND SAFETY CHECK PROCEDURE  . . . . . . . . . . . . . . . . .  9
TROUBLESHOOTING AND MAINTENANCE   . . . . . . . . . . . . . . . . . . . .  9

WIRING DIAGRAM - OIL-FIRED FURNACE   . . . . . . . . . . . . . . . . . . . . .  14

GAS CONVERSION BURNER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16

FOR YOUR SAFETY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
HOW YOUR GAS FURNACE WORKS . . . . . . . . . . . . . . . . . . . . . . . . .  16
DESCRIPTION   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  16
INSTRUCTIONS FOR EXAMINING THE FURNACE  . . . . . . . . . . . . . .  17
SEASONAL SERVICE INFORMATION   . . . . . . . . . . . . . . . . . . . . . . . .  17
START-UP AND SHUTDOWN INSTRUCTIONS  . . . . . . . . . . . . . . . . .  18
FURNACE USER MAINTENANCE  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  19
WARRANTY AND RESPONSIBILITIES  . . . . . . . . . . . . . . . . . . . . . . . .  19

SERVICE AND MAINTENANCE MANUAL  . . . . . . . . . . . . . . . . . . . . . . .  20

SAFETY SECTION  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
FURNACE MAINTENANCE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
FURNACE CLEANING  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  20
THE FURNACE CONTROLS AND THEIR FUNCTION   . . . . . . . . . . . .  20

WIRING DIAGRAM - GAS CONVERSION BURNER  . . . . . . . . . . . . . . .  21

HONEYWELL S87K PRIMARY IGNITION CONTROL 
TROUBLESHOOTING GUIDE   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  23

OIL BURNER REPAIR PARTS LIST  . . . . . . . . . . . . . . . . . . . . . . . . . . . .  26
REPLACEMENT PART CONTACT INFORMATION . . . . . . . . . . . . . . . .  27
GAS CONVERSION BURNER REPAIR PARTS LIST   . . . . . . . . . . . . . .  29
LIMITED WARRANTY  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .32

CONTACT INFORMATION FOR USA

Contact us by mail:

CONTACT INFORMATION FOR CANADA

Go to website at www.york.com click on “contact”, then click on
“contact form” and follow the instructions.

Contact us by mail:

York International

Consumer Relations

5005 York Drive

Norman, OK 73069

DISTRIBUTED BY:

StyleCrest

801 W. 37th Street

Building #7

Wichita, Ks 67219

MANUFACTURED BY:

York International

5005 York Drive

Norman, OK 73069

Содержание DFAA

Страница 1: ...eath or prop erty damage Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL FUEL OIL Do not try to light any appliance Turn off the electric switch Immediately call your service technician DO NOT start the furnace If the control reset button has been pushed more than one time the chamber may be flooded with oil ...

Страница 2: ...ency Examine the furnace as outlined below in steps 1 6 before each heating season Use Figures 2 and 3 for visual reference 1 Examine the heat exchanger through a field installed access panel located on the supply air plenum Visually examine the exte rior sections of the vent combustion air piping and the connectors to be sure that they are physically sound without holes or exces sive corrosion 2 ...

Страница 3: ...ot try to light the burner by hand 2 BEFORE OPERATING smell all around the appliance area for fuel oil Be sure to smell next to the floor because fuel oil is heavier than air and will settle on the base of the chamber Look for any oil leaks around the base of the furnace 3 Use only your hand to turn the manual oil line valve attached the pump to the on position Never use tools If the valve will no...

Страница 4: ... you must do the following 1 Before proceeding be sure the area is well ventilated Follow instruction To turn off the appliance Check all metal parts and surfaces to be sure they have cooled to room temperature before you begin 2 Remove the louvered blower door by pulling on the indentated handles on both sides of the bottom of the door 3 Remove the air filter by sliding them down The air filter w...

Страница 5: ...l safety lockout timing Check ignition system for proper operation Inspect the vent system for soot accumulation or other restriction Clean the appliance thoroughly according to the manufacturer s recommendations TABLE 1 Filter Sizes Blower Door Return inches cm 2 16 x 20 2 41 x 51 Make sure you DO NOT move the clip on weight on the indoor fan wheel when cleaning the wheel This weight is used to b...

Страница 6: ...he connector tube assembly 6 Push the nozzle assembly in at the flare fitting end until the assembly is inside the burner housing Be sure to keep the flare end at a slight angle upwards to avoid dripping oil on the combus tion air fan below 7 Slide the nozzle assembly up and out of the burner assembly Take extra precautions with the electrodes when removing the nozzle assembly so the insulators do...

Страница 7: ...coupling Do not force the pump shaft on to the coupling 22 Reinstall the nozzle assembly and tighten the assembly to the burner housing with the splined nut 23 Reconnect the connector tube assembly and tighten the flare fit ting 24 Check the transformer spring contacts If worn replace 25 Push the transformer up and forward checking to make sure the springs are touching the electrode rods 26 Put th...

Страница 8: ... 15 seconds of the primary control it will turn off the oil burner There will be 3 retries before the primary con trol will lockout If the flame is lost for 2 seconds during the 15 second stabilization period the ignition transformer is energized and a retry operation begins If flame is not detected within 15 seconds during the retry the primary control will go into recycle mode Once the primary c...

Страница 9: ...p and oil valve closes TROUBLESHOOTING AND MAINTENANCE IMPORTANT Due to the potential hazard of line voltage only a trained experienced service technician should perform the troubleshooting pro cedures IMPORTANT This control contains no field serviceable parts Do not attempt to take it apart Replace entire control if operation is not as described To completely troubleshoot an oil burner installati...

Страница 10: ... mary control by using the following equipment 1 Screwdriver 2 Voltmeter 0 to 150 VAC range 3 Insulated jumper wire with both ends stripped 4 Follow the oil burner operation and oil burner control troubleshoot ing steps in Tables 5 and 6 TABLE 4 Cad Cell Resistance When Sensing Flame Flashes Cad Cell Resistance in Ohms 1 Less than 400 2 More than 400 and less than 800 3 More than 800 and less than...

Страница 11: ... motor Flashes indicator light at 1 2 second on 1 2 second off Depress reset button to return to power up sequence c When flame is detected Carry Over period begins 5 Control enters Ignition Carry Over period continues to spark for 10 to 30 seconds a Turns on indicator light b If flame is lost and lockout time has not expired R7184 returns to Trial for Ignition period c If flame is lost and lockou...

Страница 12: ...oltage should be 120 VAC 3 Check indicator light with burner off no call for heat no flame Indicator light is on Cad cell or controller is defective sees external light or connections are shorted Go to step 4 Indicator light is off Go to step 5 4 Shield cad cell from external light Indicator light turns off Eliminate external light source or permanently shield cad cell Indicator light stays on Rep...

Страница 13: ...onnect line voltage power and close line switch d Start burner Burner locks out Go to Step 11 Burner keeps run ning System is okay 11 Check cad cell a Disconnect line voltage power and open line switch b Remove existing cad cell and replace with new cad cell c Disconnect all wires from ther mostat terminals to be sure there is no call for heat d Reconnect line voltage power and close line switch e...

Страница 14: ...107273 UUM C 0306 14 Unitary Products Group SECTION III WIRING DIAGRAM OIL FIRED FURNACE FIGURE 13 Wiring Diagram for DFAA Oil Fired Furnace ...

Страница 15: ...107273 UUM C 0306 Unitary Products Group 15 FIGURE 14 Wiring Diagram for DFAH Oil Fired Furnace ...

Страница 16: ...ase of malfunction For this reason it is never practical to assume that the furnace will operate unattended for a long period of time especially if there is a possibility of damage to your property because of freezing So if you plan to be away from home arrange for someone to check your house every day DESCRIPTION This furnace shall be installed in the downflow position Figure 17 shows a typical m...

Страница 17: ...front panels Follow the operating instructions to place the furnace in operation Observing Burner Operation 1 Observe burner to make sure it ignites Observe color of flame On natural gas the flame will burn blue with appreciably yellow tips On Propane gas a yellow flame may be expected If flame is not the proper color call a qualified service technician for service 2 Let furnace heat until blower ...

Страница 18: ...e some gas is heavier than air and will settle on the floor C Use only your hand to push the gas control switch to the on position Never use tools If the switch will not operate by hand don t try to repair it call a qualified service technician Force or attempted repair may result in a fire or explosion D Do not use this appliance if any part has been under water Immediately call a qualified servi...

Страница 19: ...ed with dust they can be brushed and cleaned with a vac uum cleaner If the blower cannot be properly cleaned without removing it from the furnace then call a qualified service agency Only a qualified service agency can perform this service Motor Lubrication The motors in these furnaces are permanently lubricated and do not require periodic oiling WARRANTY AND RESPONSIBILITIES It is the sole respon...

Страница 20: ... wrench boss on the gas valve when removing or installing this piping Refer to Figure 18 3 Unplug the black and white line voltage wires at the quick connec tor terminals Identify and note the location of all leads for ease of reinstallation 4 Unplug the red and black wires that are connected to the T T terminals on the primary control These wires can be disconnected at the quick connect terminals...

Страница 21: ...107273 UUM C 0306 Unitary Products Group 21 SECTION VI WIRING DIAGRAM GAS CONVERSION BURNER FIGURE 20 Wiring Diagram for DFAA Gas Conversion Burner ...

Страница 22: ...107273 UUM C 0306 22 Unitary Products Group FIGURE 21 Wiring Diagram for DFAH Gas Conversion Burner ...

Страница 23: ...THE 30 SECOND PREPURGE AND 8 SECOND SAFE START CHECK CYCLE 3 CHECK FOR 120 VAC AT GAS VALVE TERMINALS REPLACE PRIMARY IGNITION CONTROL CHECK ELECTRICAL WIRING AND CONNECTIONS BE SURE LEADS ARE ON CORRECT GAS VALVE TERMINALS 4 MAKE SURE LEADS ARE ON THE CORRECT GAS VALVE 5 CHECK FOR CORRECT MANIFOLD PRESSURE 6 REPLACE GAS VALVE OK OK OK OK OK NO NO NO OK OK OK NO NO NO OK OK OK OK OK OK 1 CHECK THE...

Страница 24: ...GNITION ELECTRODE ROD 6 REPLACE PRIMARY IGNITION CONTROL REPLACE PRIMARY IGNITION CONTROL CHECK THE FLAME SENSING CIRCUIT FOR 1 GROUNDED FLAMEROD 2 DAMAGE TO FLAMEROD LEAD INSULATION NOTE MAKE SURE THE FLAMEROD CIRCUIT AND OR PRIMARY CONTROL IS MOISTURE FREE 1 RESET CONTROL MOTOR STARTS AFTER 30 SECOND PREPURGE CYCLE AND 8 SECOND SAFE START CHECK MOTOR CONTINUES TO RUN BUT FLAME IS NOT ESTABLISHED...

Страница 25: ...CYCLE FLAME IS ESTABLISHED A STABLE MICROAMPERE CURRENT OF 8 OR MORE IS REQUIRED FOR DEPENDABLE OPERATION 4 MICROAMPERE READING IS LESS THAN 8 OR UNSTABLE 1 CHECK FOR PROPER THERMOSTAT INSTALLATION AND LOCATION 2 CHECK THERMOSTAT HEAT ANTICIPATOR FOR CORRECT SETTING 3 CHECK LOW VOLTAGE CIRCUIT FOR BAD WIRING ELECTRICAL CONNECTIONS AND OR SWITCHES 4 CHECK LINE VOLTAGE CIRCUIT FOR BAD WIRING ELECTRI...

Страница 26: ...06 26 Unitary Products Group SECTION VII OIL BURNER REPAIR PARTS LIST 1 3 2 2 3 2 12 9 11 10 8 7 6 5 4 13 HEAT COOL DFAA HEAT ONLY DFAH CONTROL BOX DETAIL 15 1 14 16 17 DFAA066BBTA DFAH066BBSA DFAA084BBTA DFAH084BBSA ...

Страница 27: ...witch System 7681 3301 7681 3301 1 5 Transformer 115 24V 40 VA 1 6 Filter 16x20x1 2 Req d 1214 2511 1214 2511 1 7 Panel Door Upper 7900 7631 7900 7631 1 8 Panel Door Lower Short 7900 7671 7900 7671 1 9 Motor 024 31948 000 024 31949 000 1 10 Plug Connector 025 21192 000 025 21192 000 1 11 Capacitor Run 7 5MFD 370V 024 20045 000 1 12 Wheel Blower 026 19654 003 026 19654 003 1 13 Fan Relay Blower 1 1...

Страница 28: ...0 026 39212 000 2 11 Motor Oil Burner 026 39213 000 026 39213 000 2 12 Blower Wheel 026 39214 000 026 39214 000 2 13 Coupling 026 33072 000 026 33072 000 2 14 Primary Ignition Control Valve On Delay 026 39215 000 026 39215 000 2 15 Electrical Box 026 39216 000 026 39216 000 2 16 Igniter 026 39217 000 026 39217 000 2 17 Cad Cell Detector 026 39218 000 026 39218 000 2 18 Flange Gasket 026 39219 000 ...

Страница 29: ...19 49 9 27 27 46 26 25 16 14 20 8 51 56 57 53 42 1 43 6 38 31 34 33 32 41 16 30 40 40 40 39 35 36 37 28 6 28 29 6 4 10 11 5 17 55 6 6 6 15 23 24 12 45 MINIMUM INPUT 66 000 BTU HR MAXIMUM INPUT 84 000 BTU HR ELECTRICAL POWER SUPPLY 115V 60HZ 1 FUELS NATURAL L P GAS 3 5 W C MOUNTING FIXED FLANGE f BURNER MODELS SC80 C ...

Страница 30: ...CYCLER 1 P 26 101243 001 CONTROL IGN H S87K1008 DI 1 P 27 100603 008 SCREW HXSLT 8 18 X 1 25 2 P 28 100603 001 SCREW 6 20 X 375 4 P 29 101154 001 RING BLOWER MOUNTING 1 P 30 63888 001 TUBE AIR INLET YORK 1 M 31 63887 001 DECAL AIR SETTING YORK 1 P 32 63892 001 TUBE DUCT OUTSIDE AIR 7 1 2 LG 1 P 33 63885 001 SHAFT BUTTERFLY DISC AIR 1 P 34 63884 001 DISC BUTTERFLY AIR 1 P 35 63883 001 ELBOW 1 1 2 S...

Страница 31: ...107273 UUM C 0306 Unitary Products Group 31 NOTES ...

Страница 32: ...form normal or routine maintenance as set out in the operation and service instructions 10 Cleaning replacement of filters or any other routine maintenance as set out in the User s Information Maintenance and Service Manual 11 Replacement or cleaning of nozzles or orifices 12 Fuses either internal or external to the product 13 Excessive fuel or electricity consumption THIS WARRANTY IS IN LIEU OF A...

Отзывы: