4
Rinnai Corporation EX08C, EX11C Manual
EX08C
EX11C
Application
For manufactured home (USA only) or mobile home or residential installation
convertible for use with natural gas and liquefied petroleum gases (propane / LPG)
when provision is made for the simple conversion from one gas type to the other.
For commercial setting.
For installation at altitudes up to 10,200 feet (3109 m).
General Description
Forced combustion, forced convection, flued gas furnace
Operation
Push button electronic
Gas Connection
1/2 in male NPT
Gas Control
Electronic
Burners
Stainless steel Bunsen burner
Temperature Control
Electronic thermostat, (Low, 60-80ºF in 2ºF increments, High)
Ignition System
Electronic spark ignition
Flue System
The flue must be terminated to atmosphere with only flue components listed with the
appliance’s certification. Warranty will be voided if non listed components are
installed.
Humidifier Tray
Capacity - 1.5 pints (700 cc)
Electrical Connection
AC 120V, 60 Hz, 41 watts
AC 120V, 60 Hz, 44 watts
Standby Power
0.5 watt
Weight
Noise Level
27-36 dB
31-38 dB
AFUE Rating
Natural Gas: 81%
Propane: 82%
Natural Gas: 80%
Propane: 81%
46 lbs (21 kg)
Specifications
Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.
The efficiency rating of this appliance is a product thermal efficiency rating determined under continuous operating
conditions and was determined independently of any installed system.
Safety Features
•
Overheat:
The appliance will automatically shut
down when the appliance exceeds a predetermined
temperature.
•
Flame Failure:
The appliance will automatically
shut down if the burner flame is extinguished.
•
Power Failure:
The appliance will shut off the gas
if it loses electrical power.
•
Power Surge Fuse:
A glass fuse on the PC board
protects against overcurrent. If the fuse blows then
all indicator lamps will be off.
•
Spark Detector:
The appliance automatically shuts
down if there is an abnormal spark at ignition.
•
Fusible Link:
In case the overheat feature does
not prevent an overheat then the fusible link could
break, shutting off the appliance.
Appliance Specifications
Содержание ENERGYSAVER EX08C
Страница 30: ...30 Rinnai Corporation EX08C EX11C Manual Cut Away Diagram ...
Страница 33: ...Rinnai Corporation EX08C EX11C Manual 33 Parts List For replacement parts call Rinnai at 1 800 621 9419 ...
Страница 34: ...34 Rinnai Corporation EX08C EX11C Manual Parts List ...
Страница 35: ...Rinnai Corporation EX08C EX11C Manual 35 Parts List ...
Страница 36: ...36 Rinnai Corporation EX08C EX11C Manual Parts List 164 ...
Страница 37: ...Rinnai Corporation EX08C EX11C Manual 37 Parts List ...
Страница 78: ...78 Rinnai Corporation EX08C EX11C Manual Notes ...
Страница 79: ...Rinnai Corporation EX08C EX11C Manual 79 Notes ...
Страница 80: ...RHF265 1091X01 00 Printed in Japan 2010 06 ...