Clearances

The clearances, measured from the 

edge of the glass

, are minimum clearances unless otherwise 

stated.

While the unit is operating

The fire must not be installed where curtains 

or other combustible materials could come 

into contact with the unit. The 400 mm side 

clearance includes side walls.

Floor protection

Heat from this fire may affect the appearance 

of some materials used for flooring, such 

as carpet, vinyl, cork or timber. This may be 

amplified if the air contains cooking vapours or 

cigarette smoke. To avoid this occurring, it is 

recommended that a mat be placed in front of 

the fire, extending at least 750 mm in front.

Mantels and surrounds

Mantels and surrounds, made of combustible 

materials such as wood, are allowed providing 

they are outside the minimum clearances 

shown.

Hearths

A hearth is not necessary but can be used for 

decorative purposes or protection of sensitive 

flooring. A hearth must not obscure the front 

face of the fire or obstruct the fire in any way 

(including the frame around the fire).

TV installation above the fire

The Arriva has a fan that distributes warm air 

from the bottom of the unit out into the room. 

As warm air is dispersed outwards, as opposed 

to directly upwards, installation of a TV may be 

an option.

Generally the bottom of the television should be 

at least 400 mm above the fire. Please contact 

the television supplier to check clearances. 

Some television manufacturers have warranty 

conditions that state a TV is not to be installed 

above a fireplace.

For further information please contact Rinnai or 

refer to the installation guide, which includes a 

TV installation diagram.

A

Mantel needs to be a min. of 400 mm away from 

the edge of the inner glass

B

Max. mantel depth at 400 mm (A) is 250 mm

C

Surround needs to be a min. of 400 mm away from 

the edge of the glass

For every 50 mm of added mantel depth, there must be 

an additional 100 mm of clearance from the edge of the 

glass. For example:

Mantel depth

 

A

: Clearance required

300 mm  

500 mm

350 mm  

600 mm

400 mm  

700 mm

400 mm

1000 mm

400 mm

400 mm

A

B

C

Содержание Arriva 752

Страница 1: ...Arriva 752 gas fireplace Operation guide...

Страница 2: ...and serviced by an authorised person being in New Zealand a licensed gasfitter Warning Improper installation adjustment alteration service and maintenance can cause property damage personal injury or...

Страница 3: ...ng 12 Error codes 14 Abnormal flame pattern 15 Installation checklist and installer details 16 Purchase details 17 Register your Ariiva 752 online 17 Limited Warranty 18 Contents Gas fires like cars r...

Страница 4: ...cated immediately below a power socket outlet potential fire hazard Do not restrict warm air discharge by placing articles in front of the fire Do not post or allow children to post articles into the...

Страница 5: ...Small soot deposits inside the heater or glass is normal Significant soot build up however is not normal and will require a service call Refer to the troubleshooting section for further information En...

Страница 6: ...a has the following safety devices flame failure sensing system pressure relief overheat safety switch air temperature sensor thermal fuse overcurrent fuse spark detection Positioning the Arriva 752 T...

Страница 7: ...ttempt to clean the filters with water Heater shut down due to filter blockages Do not wait for the blockage indicator error code 14 to come on before cleaning the filters and do not continue to use t...

Страница 8: ...earth must not obscure the front face of the fire or obstruct the fire in any way including the frame around the fire TV installation above the fire The Arriva has a fan that distributes warm air from...

Страница 9: ...The ignition sparker will operate as soon as a spark is sensed and gas will flow to the main burner 3 When the main burner has established the unit will automatically modulate between the burner sett...

Страница 10: ...remote is not going to be used for a long time This will help avoid damage from leaking batteries After batteries are replaced the clock and timers may need to be reprogrammed Standby On Stops and op...

Страница 11: ...Preheat automatically functions in conjunction with the timers The preheat function ensures the room reaches temperature by the programmed on time This is achieved by sensing the room temperature one...

Страница 12: ...is to allow the appliance to warm up helping avoid cold drafts Smoke or strange smells when operating after installation This is caused by grease oil or dust within the appliance This will stop after...

Страница 13: ...Fire not plugged in properly or turned off Plug in power cord or press the On Off button on the control panel Mains power failure Use power reset procedure refer p 6 Arriva stops during operation Main...

Страница 14: ...once fro standby then a second time to turn the fire on 11 Ignition failure Check gas supply is turned on switch heater to standby and then on again If ignition failure continues a service call is re...

Страница 15: ...or shifting of burn media There are some warning signs that could indicate a problem Unusual smell from the appliance Continued difficulty or delay in establishing a flame Either very short or very l...

Страница 16: ...ble location clearances mantels surrounds etc F Rinnai flue system installed and tested to ensure effective draw F Gas pressure checked and set according to the data plate F Burn media installed as pe...

Страница 17: ...dress Date of purchase Product details Record your purchase details below Register your fire online at www rinnai co nz register You ll need to know the model and also the serial number shown on the s...

Страница 18: ...ees the availability of repair facilities and spare parts for the express warranty period recorded in the table above This warranty does not limit any consumer rights or guarantees that may apply unde...

Страница 19: ...arge and cost of parts if required 1 Accidental damage and acts of God 2 Failure due to abuse or misuse improper maintenance or improper storage 3 Failure due to incorrect or unauthorised installation...

Страница 20: ...Arriva 752 operation guide 12219 C Serial number Rinnai co nz 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz...

Отзывы: