Rinnai Arriva 752 Скачать руководство пользователя страница 11

 Arriva 752 operation guide: 12219-C 03-20  |  

 11

Setting the clock

The clock must be set before 

the timers will operate.

Press the ‘Time Set’ button 

once, ‘Clock Set’ will be 

displayed to confirm the 

function is initiated. The 

remote will show ‘AM 12:00’. 

Use the up and down buttons 

to set AM or PM and set the 

clock, then press ‘Time Set’ to 

start programming the timers.

If you don’t want to set the 

timers at this point, press 

‘Time Set’ four times to return 

to the clock. If no button is 

pressed within 90 seconds, 

the screen will deactivate and 

the settings may be lost.

Setting the timers

After the clock has been set 

and the ‘Time Set’ button 

selected:

1.  ‘Timer 1 Set On’ 

and ‘AM 06:00’ 

will be displayed. 

Use the up and 

down buttons to set AM or 

PM. Press the Time Set 

button once.

 

2.  ‘Timer 1 Set Off’ 

and ‘AM 09:00’ 

will be displayed. 

Use the up and 

down buttons to set AM 

or PM. Press the Time set 

button once.

 

3. 

To set up Timer 2 repeat 

the above steps, or press 

‘Time Set’ three times to 

exit the timer program.

 

4.  The set On/Off timers 

will be displayed briefly 

to confirm the settings. 

When the programs have 

been received the remote 

display will revert to time 

mode.

Using the timers

Prior to using the timers 

ensure the desired 

temperature has been set, 

refer previous page.

You can view the timer 

settings by pressing the 

‘Timer 1’ or ‘Timer 2’ buttons 

while the fire is operating. 

The display will briefly show 

the status of each timer, i.e. 

Timer 1 On, Timer 1 Off. If the 

current time is outside of the 

programmed times the fire will 

go into standby and the LED 

will glow green.

To turn the timers off, press the 

relevant timer button again. 

The fire will return to standby. 

If there are no timers set the 

Timer Indicator will go out.

Preheat function

Preheat automatically 

functions in conjunction 

with the timers. The preheat 

function ensures the room 

reaches temperature by the 

programmed on time. This is 

achieved by sensing the room 

temperature one hour prior to 

start.

Override

This is used to manually 

override the timers so the 

fire can be operated outside 

the timer periods. When 

override is selected ‘Override’ 

will be displayed. While in 

Override all remote functions, 

except for flame function are 

available until the next timer 

period.

To return to the timer setting, 

press ‘Override’ again. If 

Standby / On is pressed 

during override the fire will 

revert to standby and the timer 

programs will be cancelled.

Extra low

Useful in situations when the 

room temperature keeps rising 

even when the fire is on the 

lowest setting.

Function off

When the room temperature 

reaches the preset 

temperature the fire continues 

to operate with the main 

burner on low, to provide a 

flame picture with minimal 

heat output. In some cases 

this may cause the room to 

become warmer than desired.

Function on

When the room temperature 

exceeds the preset 

temperature, the burner will 

reduce to an extra low setting 

and will return to normal if the 

room temperature starts to fall 

below the preset temperature.

Flame

Flame function 

can be used 

approximately 90 

seconds after the 

fire has started. The flame 

function is used to select 

a desired flame picture 

and overrides automatic 

mode

seven flame settings 

available.

While the fire is operating 

press the ‘Flame’ button. The 

fire will automatically default 

to the last flame setting. The 

word ‘Flame’ and a series of 

short bars will be displayed. 

Use the up and down buttons 

to select the desired flame 

picture. The number of bars 

illuminated will correspond to 

your selection.

Should the room temperature 

exceed 40 °C, while the flame 

function is on, the fire will 

switch off

this is a safety 

feature.

AM

Timer 1

Set ON

AM

Timer 1

Set

OFF

AM

Time

Flame

Содержание Arriva 752

Страница 1: ...Arriva 752 gas fireplace Operation guide...

Страница 2: ...and serviced by an authorised person being in New Zealand a licensed gasfitter Warning Improper installation adjustment alteration service and maintenance can cause property damage personal injury or...

Страница 3: ...ng 12 Error codes 14 Abnormal flame pattern 15 Installation checklist and installer details 16 Purchase details 17 Register your Ariiva 752 online 17 Limited Warranty 18 Contents Gas fires like cars r...

Страница 4: ...cated immediately below a power socket outlet potential fire hazard Do not restrict warm air discharge by placing articles in front of the fire Do not post or allow children to post articles into the...

Страница 5: ...Small soot deposits inside the heater or glass is normal Significant soot build up however is not normal and will require a service call Refer to the troubleshooting section for further information En...

Страница 6: ...a has the following safety devices flame failure sensing system pressure relief overheat safety switch air temperature sensor thermal fuse overcurrent fuse spark detection Positioning the Arriva 752 T...

Страница 7: ...ttempt to clean the filters with water Heater shut down due to filter blockages Do not wait for the blockage indicator error code 14 to come on before cleaning the filters and do not continue to use t...

Страница 8: ...earth must not obscure the front face of the fire or obstruct the fire in any way including the frame around the fire TV installation above the fire The Arriva has a fan that distributes warm air from...

Страница 9: ...The ignition sparker will operate as soon as a spark is sensed and gas will flow to the main burner 3 When the main burner has established the unit will automatically modulate between the burner sett...

Страница 10: ...remote is not going to be used for a long time This will help avoid damage from leaking batteries After batteries are replaced the clock and timers may need to be reprogrammed Standby On Stops and op...

Страница 11: ...Preheat automatically functions in conjunction with the timers The preheat function ensures the room reaches temperature by the programmed on time This is achieved by sensing the room temperature one...

Страница 12: ...is to allow the appliance to warm up helping avoid cold drafts Smoke or strange smells when operating after installation This is caused by grease oil or dust within the appliance This will stop after...

Страница 13: ...Fire not plugged in properly or turned off Plug in power cord or press the On Off button on the control panel Mains power failure Use power reset procedure refer p 6 Arriva stops during operation Main...

Страница 14: ...once fro standby then a second time to turn the fire on 11 Ignition failure Check gas supply is turned on switch heater to standby and then on again If ignition failure continues a service call is re...

Страница 15: ...or shifting of burn media There are some warning signs that could indicate a problem Unusual smell from the appliance Continued difficulty or delay in establishing a flame Either very short or very l...

Страница 16: ...ble location clearances mantels surrounds etc F Rinnai flue system installed and tested to ensure effective draw F Gas pressure checked and set according to the data plate F Burn media installed as pe...

Страница 17: ...dress Date of purchase Product details Record your purchase details below Register your fire online at www rinnai co nz register You ll need to know the model and also the serial number shown on the s...

Страница 18: ...ees the availability of repair facilities and spare parts for the express warranty period recorded in the table above This warranty does not limit any consumer rights or guarantees that may apply unde...

Страница 19: ...arge and cost of parts if required 1 Accidental damage and acts of God 2 Failure due to abuse or misuse improper maintenance or improper storage 3 Failure due to incorrect or unauthorised installation...

Страница 20: ...Arriva 752 operation guide 12219 C Serial number Rinnai co nz 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz...

Отзывы: