Limited Warranty

Rinnai brings you peace of mind with a:

5-year firebox warranty

This warranty is applicable to all Rinnai gas fires manufactured from 01 May 2019. All terms of 

the warranty, subject to the conditions below, are effective from the date of first installation. The 

attending service person reserves the right to verify this by requesting a copy of the gas certificate 

of compliance prior to commencement of any warranty work. Proof of purchase and installation date 

will be required at the time of any warranty claim. This warranty is only valid within the country of 

purchase. 

FIREBOX

1

ALL OTHER PARTS

Parts

Labour

Parts

Labour

 5 years

2

2 years

2

2 years

2

2 years

2

1

 

The firebox is the metal outer casing that surrounds the fire. All other parts of the fire will be covered by a two year limited

 

   warranty

2

 From date of first installation

General warranty terms

All Rinnai appliances meet or exceed the safety standards required by New Zealand gas and 

electrical regulations. The company is constantly improving its products and as such, specifications 

are subject to change or variation without notice.  

For the purposes of the Consumer Guarantees Act 1993, Rinnai only guarantees the availability of 

repair facilities and spare parts for the express warranty period recorded in the table above. 

This warranty does not limit any consumer rights or guarantees that may apply under the 

Consumer Guarantees Act 1993. If the product is acquired for the purposes of a business, the 

provisions of the Consumer Guarantees Act 1993 do not apply and no other warranties (either 

express or implied by law) apart from those stated in the warranty will apply. 

Warranty terms and conditions

1.  All terms of this warranty are effective from the date of first installation. The attending service 

person reserves the right to verify this by requesting a copy of the gas certificate of compliance 

prior to commencement of any warranty work. The installer must issue a certificate of 

compliance by law in New Zealand.  Warranty claims may be invalid if not accompanied by 

details of the installing or supervising gas fitter’s registration number and the gas certification 

number.

2. 

All Rinnai appliances must be installed, commissioned, serviced, repaired and removed in 

accordance with the manufacturer’s installation instructions, local regulations, and building 

codes by persons authorised by local regulations to do so. 

3. 

All appliances must be operated and maintained in accordance with the manufacturer’s 

operating instructions. Rinnai recommends that gas fires are serviced every two years, 

including inspection of the flue system.

Содержание Arriva 752

Страница 1: ...Arriva 752 gas fireplace Operation guide...

Страница 2: ...and serviced by an authorised person being in New Zealand a licensed gasfitter Warning Improper installation adjustment alteration service and maintenance can cause property damage personal injury or...

Страница 3: ...ng 12 Error codes 14 Abnormal flame pattern 15 Installation checklist and installer details 16 Purchase details 17 Register your Ariiva 752 online 17 Limited Warranty 18 Contents Gas fires like cars r...

Страница 4: ...cated immediately below a power socket outlet potential fire hazard Do not restrict warm air discharge by placing articles in front of the fire Do not post or allow children to post articles into the...

Страница 5: ...Small soot deposits inside the heater or glass is normal Significant soot build up however is not normal and will require a service call Refer to the troubleshooting section for further information En...

Страница 6: ...a has the following safety devices flame failure sensing system pressure relief overheat safety switch air temperature sensor thermal fuse overcurrent fuse spark detection Positioning the Arriva 752 T...

Страница 7: ...ttempt to clean the filters with water Heater shut down due to filter blockages Do not wait for the blockage indicator error code 14 to come on before cleaning the filters and do not continue to use t...

Страница 8: ...earth must not obscure the front face of the fire or obstruct the fire in any way including the frame around the fire TV installation above the fire The Arriva has a fan that distributes warm air from...

Страница 9: ...The ignition sparker will operate as soon as a spark is sensed and gas will flow to the main burner 3 When the main burner has established the unit will automatically modulate between the burner sett...

Страница 10: ...remote is not going to be used for a long time This will help avoid damage from leaking batteries After batteries are replaced the clock and timers may need to be reprogrammed Standby On Stops and op...

Страница 11: ...Preheat automatically functions in conjunction with the timers The preheat function ensures the room reaches temperature by the programmed on time This is achieved by sensing the room temperature one...

Страница 12: ...is to allow the appliance to warm up helping avoid cold drafts Smoke or strange smells when operating after installation This is caused by grease oil or dust within the appliance This will stop after...

Страница 13: ...Fire not plugged in properly or turned off Plug in power cord or press the On Off button on the control panel Mains power failure Use power reset procedure refer p 6 Arriva stops during operation Main...

Страница 14: ...once fro standby then a second time to turn the fire on 11 Ignition failure Check gas supply is turned on switch heater to standby and then on again If ignition failure continues a service call is re...

Страница 15: ...or shifting of burn media There are some warning signs that could indicate a problem Unusual smell from the appliance Continued difficulty or delay in establishing a flame Either very short or very l...

Страница 16: ...ble location clearances mantels surrounds etc F Rinnai flue system installed and tested to ensure effective draw F Gas pressure checked and set according to the data plate F Burn media installed as pe...

Страница 17: ...dress Date of purchase Product details Record your purchase details below Register your fire online at www rinnai co nz register You ll need to know the model and also the serial number shown on the s...

Страница 18: ...ees the availability of repair facilities and spare parts for the express warranty period recorded in the table above This warranty does not limit any consumer rights or guarantees that may apply unde...

Страница 19: ...arge and cost of parts if required 1 Accidental damage and acts of God 2 Failure due to abuse or misuse improper maintenance or improper storage 3 Failure due to incorrect or unauthorised installation...

Страница 20: ...Arriva 752 operation guide 12219 C Serial number Rinnai co nz 0800 746 624 http www youtube com rinnainz http www facebook com rinnainz...

Отзывы: