Ignition
Firmly press the IGN button for 10 seconds and release. This operates the built-in safety
device and starts the electronic spark (lights to pilot).
If the pilot does not remain alight, wait 2 minutes before retrying ignition. If the heater does
not ignite on initial use it may be due to air remaining in the gas supply line.
HIGH
LOW
IGN
Adjusting the heat
Press the buttons from ‘LOW’ to ‘HIGH’. This will ignite additional burners as shown above.
Turning off
Press and release the buttons from ‘HIGH’ to ‘IGN’ until they are in the off position. The fan
will stop when the heater cools.
Fan operation
The fan will operate automatically when the heater warms up and will stop when it cools.
When the heater is on the ‘LOW’ setting the fan may turn off as the heater cools and restart
when warm.
In the event of a power failure
If there is a power failure, turning the heater to the ‘LOW’ setting may allow the heater
to continue operating without overheating. Remaining on the ‘HIGH’ setting will cause the
overheat protection switch to activate. This will shut down the appliance.