Rinnai New Zealand
Continuous Flow Water Heater Operation Manual
01-09
7
General Information
Installation by a licensed tradesperson
Improper installation, adjustment, service or maintenance can cause serious injury, property
damage or death. Please ensure your installation is completed by a licensed tradesperson.
Frost kits
Frost protection is fitted as standard on all models. Frost protection oper
ates
automatically (as required) whenever the appliance is connected to the electric power
supply.
If power has failed and there is a risk of damage from frost, turn off the gas supply to the unit
and open a tap slightly to allow flow through the unit. This m
ay prevent damage from freezing.
If the appliance is not going to be used for an extended period and the electric power supply
is disconnected, turn off the water and gas supplies and arrange for your plumber to drain all
water from the appliance to prevent frost damage.
If for practical reasons a plumber is unable to drain your system we have an instruction sheet
on how to drain the unit at the back of this manual.
Safety devices
Y
our Rinnai continuous flow
water heater has the following safety devices.
Flame failure
- flame rod
Boil-dry protection
- w
ater flow sensor
Overheat protection (OHS)
- 97 °C bi-metal switch
Overheat protection
- 95 °C lockout thermistor
Fusible link
- 129 °C thermal fuse
Pressure relief valve
- open 2.1 MPa / close 1.5 MPa
Combustion fan rpm check
- integrated circuit system
•
•
•
•
•
•
•
Filter
Drain
Gas
Valve
Gas
Cold
Hot
Turn Water Off
Turn Gas Off
Drain Water