ELECTRICAL INSTALLATION

ELECTRICAL INSTALLATION

Before installing the water heater, make sure that your 

home has enough power to handle the maximum current 

available for this product.

As with all high-power electrical products, Make sure to 

turn off all power to the product directly at the fuse or 

breaker box before installing, repairing or disassembling 

this water heater.

All circuit protection (breakers) and wiring (wire gauge) 

must conform to the US National Electrical Code (NEC) in 

the America or Canadian Electrical Code (CEC) in the 

Canada . 

Failure to comply with these warnings can lead to the 

risks include fire, electrical shock and/or death and 

void your warranty.

Before starting the electrical installation work, make sure 

that all water pipelines have been installed and the main 

circuit breaker and power switch have been closed to 

prevent electric shock.

CAUTION:

 Ensure that you have made the correct 

connections. You must follow the wire connection as 

shown in ensure proper operation of the unit.

WARNING: 

For supply connections use 8 AWG or larger 

wires suitable for at least 160°F (75°C).

WARNING: 

This product has more than one power-supply 

connection point. Disconnect all power supplies before 

servicing.

WARNING: 

The overcurrent protective devices are 

provided as a separate assembly, the product shall be 

used only with this separate assembly.

WARNING: 

Firstly turn on the water and let it to run in the 

product for several minutes, and exhaust all the air in the 

plumbing. At the same time, check whether there is water 

leakage at the internal and external water connections of 

the product.

WARNING: 

To avoid a short circuit and damage the circuit 

board, make sure all strands are secure inside the terminal 

block.

L2

connector

L1

L2

L1

L2

L1

R1

R3

G

R2

heating 

element

heating 

element

heating 

element

PCB 3

PCB 3

PCB 3

PCB 1

thermal cut-out

thermal cut-out 

thermal cut-out 

t0

t1

flow sensor

temperature 

sensor

PCB 2

triac

triac

triac

EI18

EI24

L2

connector

L1

L2

L1

heating

element 

heating

element 

R1

G

R2

PCB 3

PCB 3

PCB 1

thermal cut-out

thermal cut-out

t0

t1

flow

sensor

temperature

sensor 

PCB 2

triac

triac

NOTE: The rated voltage is 240VAC. If the connected 

power supply is 208VAC, please turn the dial switch 

on the display PCB to the upper side with a slotted

screwdriver

Circuit Diagram

Wiring diagram

208VAC

240VAC

8888

208VAC

240VAC

G

L2

L1

L2

L1

L2

L1

1

2

3

4

5

6

G

L2

L1

L2

L1

1

2

3

4

EI18

EI24

Circuit Connection

1. Connect each group of power wires to a circuit breaker 

in pairs (show as below). Make sure that each circuit 

breaker is connected one group of L1 and L2.

EI18 need two circuit breakers.

EI24 need three circuit breakers.

2. When connecting the power cords to the terminal block, 

make sure that the wire and the electric conductor inside 

the terminal block are in full contact. Then tighten the 

screws. If it is loose, May causing electrical short circuit 

and/or the terminal block burn out.

Circuit

breaker

Circuit

breaker

Circuit

breaker

G

L2

L1

L2

L1

L2

L1

1

2

3

4

5

6

Ground

Circuit

breaker

Circuit

breaker

Ground

G

L2

L1

L2

L1

1

2

3

4

EI18

EI24

3. Again make sure that the wiring from the main circuit 

breaker to the water heater is correct. If the wrong wires is 

connected, the product will not work normally and may 

cause unnecessary danger.

4. Check earth resistance and make sure there is a proper 

earth continuity.

5. Confirm that all the air has been purged from the water 

lines prior to turning on power to the unit.

Содержание EI18

Страница 1: ... understand the installation and safety manual thoroughly and carefully The manual contains important safety tips and instructions INSTALLATION AND USER INSTRUCTIONS TANKLESS ELECTRIC WATER HEATERS READ AND SAVE THESE INSTRUCTIONS Installer Leave this manual with the homeowner EI18 EI24 Model 8888 ...

Страница 2: ...appliance basic safety precautions should always be followed DO NOT install this unit in a location where it may be subject to freezing temperatures If the water inside your tankless water heater freezes it can cause severe and permanent damage that is not covered under your warranty Water temperature over 125 F 52 C can cause severe scalding If the set temperature of the unit is too high there is...

Страница 3: ... be installed in the vertical position of the water pipe joint This unit has more than one power supply connection point Disconnect all power supplies before servicing WARNING To avoid damage the unit needs to be kept dry Keep unit away from direct sunlight moisture dust steam and other liquids WARNING The unit do not installed in places with water leaks such as under air conditioning lines that m...

Страница 4: ...roved vacuum breaker or other such method as proved effective by test WARNING Pipe dope or PVC CPVC primer and glue is not allowed to used on the threads of the outlet and inlet fittings These chemicals can damage the nipples and cause leaks Only thread sealing tape can be used SUGGESTION To avoid the property damage caused by leakage small probability event the machine needs to be installed in pl...

Страница 5: ...circuit and damage the circuit board make sure all strands are secure inside the terminal block L2 connector L1 L2 L1 L2 L1 R1 R3 G R2 heating element heating element heating element PCB 3 PCB 3 PCB 3 PCB 1 thermal cut out thermal cut out thermal cut out t0 t1 flow sensor temperature sensor PCB 2 triac triac triac EI18 EI24 L2 connector L1 L2 L1 heating element heating element R1 G R2 PCB 3 PCB 3 ...

Страница 6: ... service outlook com 4 Check the power supply 5 Replace temperature sensor 6 Replace heating element Water leakage at the inlet and outlet connector 1 The connector is not installed in place 2 Seal damage 1 Tighten the connector 2 Replace the seal The unit does not work Power indicator is NOT on Incorrect power wiring connection or no power Water heater is not heating at all Power indicator is on ...

Страница 7: ...pper Min Water Flow Water connection Watts Temp Rise EI18 Model 1 5GPM 2 25GPM 3 0GPM 3 4 NPT 208V 240V 208V 240V 2x38A 2x33A 18 0kW 13 5kW 80 54 40 60 40 30 0 66GPM 2 5L min Working pressure 150PSI 10BAR 2x8AWG EI24 3x34A 24 0kW 92 73 54 3x29A 18 0kW 80 53 40 3x8AWG Voltage ...

Страница 8: ...Cod 0020300897 rinkmo service outlook com ...

Отзывы: