Installation and operating instructions for
Brake HW 165 FHM spring activated
–
hydraulically released
E 09.774e
Issue: 08.01.2021
Version: 1
Drawn: BAHS
Checked: EISF Pages: 24
Page: 13
2.4.4 Control of the general running
Important!
Be Careful: The disc must be degreased and free from any deposits so as
not to decrease the friction coefficient.
Check the well running of the electric contacts.
Run the brake under no-load with the disc turning, 20 or so times, to bed in the pads.
Information!
THE SYSTEM IS NOW OPERATIONNAL
3
Operational RUNNING
3.1 Caliper tightening
The lack of hydraulic pressure allows the pads to be tightened on the disc.
The opening contact is not activated.
3.2 Caliper untightening
Apply a minimum pressure of 200bars to release the brake.
The opening contact is activated.
3.3 Caliper manual release
Manual release keeps the caliper open without hydraulic pressure.
Refer to chapter 5.1 and chapter 5.2.