background image

the system time; 
Press SET key and then set minute value in the same method. 

6.

 

Daytime time setting: 

A. Start time setting: Press SET key, 

  and 

  icon flashing, at the same time FROM flashing and 

display default hour value, press UP or DOWN key to modify the value. 
After hour set, press SET key to set the minute, press UP or DOWN key to set the value; 
B. End time setting: When start time is already finished, press SET key and then  TO icon flashing, you 
can set end time with the same method of start time setting. 

7.

 

Night time time setting: 

A. Start time setting: Press SET key, 

  and 

  icon flashing, at the same time FROM flashing and 

display default hour value, press UP or DOWN key to modify the value. 
After hour set, press SET key to set the minute, press UP or DOWN key to set the value; 
B. End time setting: When start time is already  finished, press SET key and then TO icon flashing, you 
can set end time with the same method of start time setting. 

Tips: 

1. If current menu don’t need adjustment, press SET key directly to switch to next menu, press SET key 
for 3 seconds to exit and save settings. 
2. Parameters of temperature and timer can be recycled view by pressing UP or DOWN key in normal 
status. 
3.  The  product  returns  to  normal  working  condition  automatically  without  any  key  operate  in  15 
seconds. 
4. Parameter adjustment: Press UP or DOWN key and hold, enter into quickly adjusting state. 

 

Set high and low limits of the set temperature: 

In normal working status: 

A. High  limit:  Press UP key  for 5 seconds  to  display  current  high temperature  limit  setting(50

), and 

then press UP or DOWN key to modify the set value. 

B. Low limit: Press DOWN key for 5 seconds to display original low temperature limit setting(0

), and 

then press UP or DOWN key to modify the set value. 

For example: if the limits are default value, the set temperature can be adjusted between 0~50

; if the 

high limit is 30C, low limit is 10C, the set temperature can only be adjusted between 10~30

 

 

Heat controlling function: 

Heating systems works in below situation: 

the measuring temperature 

  the set temperature 

Heating systems stops working in below situation: 

the measuring temperature 

  the set temperature 

 

Timing setting: 

FROM: timing of turning on light; TO: timing of turning off light 
If  the  system  time  is  during  FROM  time  and  TO  time,  the  light  will  light  when  timing  setting  has 
adjusted  and  saved.  For  example,  original  timing  starting  time  is  8:30,  original  timing  ending  time  is 

18:30, new timing starting time is 6:00, new timing ending time is 18:00, the system time is 7:00, you 
will see the light is on. If not, the light is off. 

Others: 

1.  Over  temperature  alarm:  upper  part  of 

  icon  rapid  flashing  with  "drops"  alarm  sounds  and 

display the measuring temperature in below situation: 

A. the measuring temperature 

  the set tempe Alarm over temperature 

B. the measuring temperature 

  the set temperature - Alarm over temperature 

2. Exceed temperature measuring limits alarm:    with "drops" alarm sounds at the same time. 

the measuring temperature 

0.0

, display LLL: super low temperature; 

the measuring temperature 

50.0

, display HHH: super high temperature; 

3.  Probe  fault  alarm:  when  probe  have  open  circuit  or  short  circuit  faulty,  display  error  message  of 
probe faulty "ERR" 

 

Mute alarming manually: 

A.  the  1

st

  and  2

nd

  alarm  can  be  muted  by  pressing  any  key,  but  probe  fault  alarm  sound  cannot 

eliminate. 
B. Press UP or DOWN key at the same time for 3 sec or more, the menu is available to choose whether 
to eliminate alarm sound, AL: have alarm sounds, NO: have no alarm sounds. 
C. You can choose one and press SET to save and exit. 

 

Socket output control load: 

I: heating output; II: timer output, such as lighting or oxygen pump. 

 

Remarks : 

When you choose a heater, please choose appropriate capacity one, for low capacity one will take 
very long time to reach the setting temp., but the high capacity one will make DTC-100 always working 
at low capacity, So such unsuitable capacity of the heater/cooler will influence the heating / cooling 
effect, and even cause damage to the heater/cooler and DTC-120 if you use them for long time. 

Safety regulations: 

 

Dangers: 

1. Please avoid overload, load short circuit, misuse, human damage etc., which is not covered by the 
warranty. Load short circuit can damage the dimming output immediately! 
2. DO NOT connect the wire terminals without electricity cut-off. 

 

Warning: DO NOT use the machine under the environment of over damp, high temp, strong 
electromagnetism interference or strong corrosion. 

 

Notes: 

1. The power supply should conform to the voltage value indicated in the instruction and keep stability 
2. To avoid the interference, the sensor down-lead and power wire should be kept a distance. 
 

 