3
5. OPERATION
1. Ensure that the inverter power on/off switch is in the OFF (0) position.
2. Plug the appliance into the AC output socket on the inverter, ensuring it does not exceed the maximum
output power of the inverter
3. Turn the power on/off switch to the ON (I) position.
4. The Power indicator will illuminate green and mains power will be available from the AC output socket(s)
6. INDICATORS & WARNINGS
Power:
Illuminates green to show the unit is switched on and power is available from the AC output
socket(s)
Over load:
Illuminates red if the units has been overloaded due to excessive current or a short circuit
Over temperature:
Illuminates yellow if the unit has overheated
Audible alarm:
An alarm sound will be heard if the unit has switched off due to a fault
Power
Indicator
Overload
Indicator
Over
Temperature
Indicator
Fault Modes
Action
Green
Off
Off
Normal Operation
-
Orange
Off
Off
Low voltage warning
Check for low battery voltage.
Check cable connections are not loose.
Reduce load if possible to extend battery life.
Red
Off
Off
Low voltage shutdown
High voltage shutdown
Switch inverter off, re-charge battery then switch back
on. Check battery voltage is correct for inverter model i.e.
24volt battery > 24volt inverter.
Red
Red
Off
Overload
Short circuit
Disconnect all loads, switch inverter off then back on.
If overload indicator is now off:
1. Total load exceeded inverters continuous rating.
2. Appliance startup current exceeded inverters surge rating.
3. A connected appliance may have an
electrical fault, test appliances before re-connecting
Red
Off
Yellow
Over temperature
Check for adequate ventilation around inverter
Check inverter cooling fans are working.
7. SPECIFICATIONS
Model
600 Watt
1000 Watt
2000 Watt
3000 Watt
Continuous Power (up to 12 hours)
600W
1000W
2000W
3000W
Surge Power (up to 1 second)
1200W
2000W
4000W
6000W
Output Voltage
230V AC±10%
Output Frequency
50Hz
Output Waveform
Pure Sine Wave
Input Voltage Range
12volt:
10V - 16V
24volt:
20V - 30V
Efficiency
> 85%
No Load Current Draw
12volt:
< 0.6amp
< 1.3amp
< 1.5amp
< 1.5amp
24volt:
-
< 1.0amp
< 1.0amp
-
RCD tripping *
-
30mA
-
Low Battery Alarm
12volt:
10.5 ± 1 volt
24volt:
21.0 ± 1 volt
Low Battery Shutdown
12volt:
10.0 ± 1 volt
24volt:
20.0 ± 1 volt
Thermal protection
60± 10
o
C
USB Port
2amp (max)
2amp (max)
-
-
Dimension (L x W x H)
255 x 225 x 91
394 x 224 x 96
385 x 290 x 96
520 x 286 x 96
Weight
3.5kg
6.3kg
7.7kg
10.8kg
* - only fitted to models RINVPR1000/RINVPR1024/RINVPR2000/RINVPR2024
36pp A5 (PSW) EURO Quick Start Handbook v4.indd 3