![RinG-MASTER RM5000EX Скачать руководство пользователя страница 32](http://html.mh-extra.com/html/ring-master/rm5000ex/rm5000ex_operation-manual_1462265032.webp)
RM5000EX Operations Manual September 2018
GROUP CONFERENCE
HANDSETS
Group Conference may be used for Emergency Communication/Paging.
Example:
10
AA918 Master station with Annunciator for display of Faults DAD104 ($09).
11-16 GS921DAM Handset Stations with Push ToTalk button.
17-20 IF935 Paging Interface.
Programming:
Master station 10.
SNA 10 1 09 (DAD assigned to master statation)
SPT 10 7 + (Activate Personal Que)
SPT 10 5 + (Activate Group Call Access)
Handset Stations 11-16.
SDT 11-16 7 (Direct Access Master)
SDA 11-16 10 (Faults are sent to 10)
SPT 11-16 10 + (Line Supervision)
SPT 11-16 5 + (Activate Group Call Access)
SDD 11-16 1 71 (Call Group Call 71 when handset is lifted)
Paging Interface 17-20.
SDT 17-20 1 (Sub)
SDA 17-20 10 (Faults are sent to 10)
SPT 17-20 10 + (Line Supervision)
Group Call 1 (71).
SGCM 10-20 1 + (Include stations 10 -20 in group call #1)
SGCP 1 2 + (T button must be used when talking)
SGCP 1 3 + (Activate Group Conference)
SST 10-20 4 30 (Set Group Call time limit to 30 seconds)
REMOTE HANDSET
The GS921DAM Handset Station may be remotely located using two
telephone dialers DNA934P.
Connect one DNA934P at the Exchange with SW3-3 ON.
Connect one DNA934P at the remote GS921DAM with SW3-4 ON.
Program each DNA934P to dial the other DNA934P.
REMOTE Conference Telephone Monitoring
Connect one DNA934P at the Exchange with SW3-2 ON.
Program the DNA934P to dial the Telephone used for Monitoring.
Page32