16
5. FITTING OPTIONS
MAKING AN EXTERNAL
COMBUSTION AIR FEED
(Optional: Fig: Panel)
->
Dismantle the rear wall as follows: Remove the 4
decorative screws and silicone disks (Item 47, 48)
and lift the Ceran area off (Item 44). Then slacken
the 4 hexagon bolts (Item 49) and remove the lid
(Item 43). No simply pull the rear wall upward out of
the aluminium profiles (Item 50).
->
Cut out the pre-stamped, round section in the
rear wall (Item 46) [metal cutting saw blade].
Fasten the fresh air nozzle (must be ordered as an
option) using the screws supplied and refit it to the
rear wall.
->
Connect a non-flammable pipe to the fresh air
nozzle (e.g.: Steel spiral pipe) and fix this using a
hose clip (not included in delivery!)
->
The line should not be longer than 4 m and have
no bends in order to guarantee adequate air feed.
->
Should the pipe lead into the open air it must end
with a vertical 90°-downward or with a cowl.
Take strictly care on sufficient air intake! It is
not permitted to close the air intake opening!