7. PROBLEM SOLVING 

 

 
WHAT TO DO IF… 

 

Problem

 

Reason

 

Solution

 

 
1. Ceramic glass soots over too 
quickly

 

 
 
 
 

Poor air movement 

 
 

Incorrect regulation 

 
 
 
 
 

Too much fuel 

 

Moist wood

 

Always: Every glass plate must be cleaned from 
time to time (depending on use) with RIKA glass 
cleaner

 

 
Clarification with chimney sweep (possible raising 
of chimney) 
 
Regulate according to instructions for regulator 
knob (if secondary air is closed, the glass plate 
soots over very quickly, but burns off again is 
operation is correct) 
 
See “Maximum fuel quantities”

 

 
See “Clean burning“, possibly use wood bri-
quettes (are evenly dry) 

 

 
2. Stove does not draw properly

 

 

Chimney draught insufficient 

 

Stove is sooted over inside 

 

 
See “A small study of heating” 
 
See “Maintenance and cleaning”

 

 

 
3. Stove does not start burning 
properly

 

 

Weather influence 

 

Incorrect heating up 

 

 
See “Fire lighting” 
 
See “Fire lighting”

 

 

 
4. Stove smells strongly and 
smokes outside

 

 

Burning-in phase 

 

Stove is dusty/dirty

 

 
See “Operation” (curing of coating)

 

 
See “Convection air openings” 

 

 
5. Coating does not cure

 

 

Burning-in phase was not com-

pleted properly

 

 
See “Operation”

 

(curing of coating) 

 

 
6. Flue gas discharge when wood 
is added and during heating

 

 

Chimney draught too low, flue 

pipe connection leaky

 

 
Check connections and if necessary re-seal 

 

 

If you do not obtain a proper solution to your problem despite this information, contact your specialist dealer or master chimney 
swe

ep. 

Содержание VITRA

Страница 1: ...1 VITRA Instruction manual ...

Страница 2: ...2 ...

Страница 3: ...3 Flue pipe connec tion with original angle pipe Connection dimensiones ...

Страница 4: ...4 Furnance door ...

Страница 5: ...5 Furnance Casing 55 54 ...

Страница 6: ...al combustion air feed 12 4 Operation Lighting the fire 13 Ash drawer 14 Operating the shaker grate 14 Rotary control knob 14 5 FITTING OPTIONS Changing flue pipe connection above to connection at rear 15 6 MAINTENANCE AND CLEANING General maintenance 16 Finish condition and cleaning 16 Convection air openings 16 Cleaning the flue gas channels 16 7 PROBLEM SOLVING What to do if 17 8 GUARANTEE AND ...

Страница 7: ...re 214 2 C Minimum flow pressure at rated heating ca pacity 12 Pa The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it to the authorities or the chimney sweep on request PARTS OVERVIEW Description 01 Furnance door machined Z33564 02 Door glass Z33465 03 Glass holder L00475 04 Lens head screw with ISK 10883...

Страница 8: ...bustion or introduction of highly flammable or explosive materials such as empty spray cans etc in the combustion chamber and storing them near the stove is strictly prohibited due to the danger of explo sion No light or inflammable clothing is to be worn when post heating Placing non heat resistant objects on the stove or near it is prohibited Do not place clothing on the stove to dry Stands for ...

Страница 9: ... fires BA 1 These fires must only be operated with the fire door closed 1 8 The fire door must only be opened for adding fuel and must then be closed again as this could otherwise lead to a danger to other fires that are also connected to the chimney 1 8 1 When the fire is not in operation the fire door must be kept closed 1 9 When using wet fuel and if operation is throttled too much the chimney ...

Страница 10: ...WOOD TYPES Different types of wood have different fuel values Decidu ous wood is particularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all soft woods and tends to spray sparks MAXIMUM FUEL QUANTITIES Wood 2 logs of approx 0 6 kg Wood briquettes broken 2 pieces of approx 0 6 kg The output of your stov...

Страница 11: ...mage or soiling of the fire and chimney as well as the environment 2 THE RIGHT QUANTITY OF FIREWOOD AND FIREWOOD DIMENSIONS Too much firewood leads to overheating This stresses the material too much and leads to poor flue gas values Too little firewood or logs being too large means the stove does not reach optimum operating temperature The flue gas values are also poor in this case The right quant...

Страница 12: ...nnection may not project into the chimney shaft Seal the gap between flue pipe and wall liner with ceramic sealer The installation must conform to the respective safety and building regulations Please contact your master chimney sweep in this context He will be pleased to inform you If you use a system chimney e g glazed fireclay we would ask you follow the manufacturer s connection instructions c...

Страница 13: ...olours pro duce very poisonous substances in the flue gas 3 Now light the paper Wait until the soft wood chips are burning well Close the shaker grate handle and the pri mary air slide a few minutes later Set the secondary air slide to the ideal setting a few minutes later 4 After this has burned lay approx 1 3 kg wood 2 billets on the fire Open the shaker grate handle and the primary air slide un...

Страница 14: ...heating loss of warranty Caution Embers could remain in the ash Only fill the ash into non flammable containers and do not put the ash onto flammable surfaces OPERATING THE SHAKER GRATE Page 4 Part 27 The ash is moved from the fire into the ash drawer by moving the shaker grate handle to and fro This frees up room for the primary feed air that is required for the heat ing phase in the fire The sha...

Страница 15: ...l part 46 using a hacksaw Please remember when changing the flue pipe connec tion that the individual parts of the soapstone panel ling weight about 34 kg In addition the surfaceof the soapstone should be protected to prevent scratching Swap the flue gas connector and the hob part 51 53 with each other Fit the new plate fins part 43 must be optionally or dered Make sure your fingers do not become ...

Страница 16: ...ss cleaner can be obtained from your special ist fire dealer Should the glass become heavily sooted the possible cause could be damp wood The fire finish is highly refractory and must only be cleaned using a cloth damp if necessary Only use original paint for touch up work this is available from your specialist dealer as an accessory Under no circumstances must the paint be cleaned before heating ...

Страница 17: ...y 2 Stove does not draw properly Chimney draught insufficient Stove is sooted over inside See A small study of heating See Maintenance and cleaning 3 Stove does not start burning properly Weather influence Incorrect heating up See Fire lighting See Fire lighting 4 Stove smells strongly and smokes outside Burning in phase Stove is dusty dirty See Operation curing of coating See Convection air openi...

Страница 18: ...at the time of purcha se Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts affected by fire are excluded such as glass coating surface coatings e g handles panels seals fire trough grates draught plates deflector plates combustion chamber liners e g fireclay c...

Страница 19: ...19 ...

Страница 20: ...20 G U A R A N T E E G A R A N T I E Customer Client To A Stamp Marque Z33571 2011 05 05 ...

Отзывы: