RIKA VITRA Скачать руководство пользователя страница 12

 

12 

 

E

N

G

L

IS

H

 

 

 

3 .   I N S T A L L A T I N G   T H E   F I R E

 

 

Before first commissioning or after changing the loca-

tion of the fire, cleaning and service work, ensure that 
the flue plate, as well as the wood stop (Fig. Combus-

tion chamber, Part 47 and 31) is in the correct position. 
When using a flue pipe with throttle valve, the throttle 
valve must be open.

 

 

Care must be taken with this fire that the flue draught 

reaches at least the prescribed value (> 10 Pa). Should 
problems arise here, please contact your master chim-
ney sweep.

 

 
 
 

CONNECTING THE FIRE 

 
Proceed  as  follows  for  new  connections  in  a  brick-built 
chimney: 
 
1.  Measure  and  mark  out  the  stove  connection  (take  into 
consideration any floor plate thickness) according to natu-
ral dimensions. 
 
2. Chisel out (drill) the hole in the brickwork. 
 
3. Brick in the wall liner. 
 

First seal the wall lining using mineral wool insulation. 
Afterwards plaster using heat resistant cement mortar 
or equivalent. 

 
4. After the mortar has hardened, and after plastering and 
painting,  position  the  floor  plate  including  the  floor  pro 
tection (carton). 
 
5. The fire can now be lifted onto the floor plate carefully. 
 

The  stove  should  not  be  pushed  on  unprotected 
floors. 
 

 

Strong  corrugated  cardboard  or  e.g.  old  carpet  is 

useful  to  assist  assembly  and  as  a  base.  The  stove 
can also be pushed on this cardboard or carpet.

 

 
We  recommend  original  flue  pipes  from  RIKA  for  proper 
connection. 
The  connection  may  not  project  into  the  chimney  shaft! 
Seal the gap between flue pipe and wall liner with ceramic 
sealer. 
 

The installation must conform to the respective safety 
and building regulations.  
Please  contact  your  master  chimney  sweep  in  this 
context. He will be pleased to inform you.

 

 
If  you  use  a  system  chimney  (e.g. glazed  fireclay)  we 
would  ask  you  follow  the  manufacturer’s  connection 
instructions closely. 
 

 
 

 

MAKING  AN  EXTERNAL  COMBUS-
TION AIR FEED 

 
-  Cut  the  perforated  part  from  the  rear  panel  by  using  a  
saw blade (part 46). 
 
- Remove the rear cover (part 60), (4 x Philips screw) and 
replace it with the one shown in the illustration (air suction 
connector obtainable from dealer Z32671). 
 
-  Tighten  the  non-flammable  pipe  Ø125  (e.g.  steel  spiral 
pipe) and attach with a hose clip (not included in delivery!) 
 
-  The  line  should  not  be  longer  than  4  m  and  have  no 
bends in order to guarantee adequate air feed. 
 
- Should the pipe lead into the open air it must end with a 
vertical 90°-downward or with a cowl. 
 
-  If  the  stove  is  connected  to  an  external  combustion  air 
subbly, then the rotating assembly must be locked using a 
fastening screw. 

 

Note: 

Please note that problems may arise due to updrafts in the 
case of combustion air supply from an integrated chimney 
ventilation shaft. If the combustion air flowing downwards 
is heated it may rise and thus counter the chimney with a 
resistance which in turn reduces the negative pressure in 
the combustion chamber. The chimney manufacturer is to 
guarantee that the resistance for the combustion air is a 
maximum 2 Pa even in the least favourable operating state 
of the chimney. 

Содержание VITRA

Страница 1: ...1 VITRA Instruction manual ...

Страница 2: ...2 ...

Страница 3: ...3 Flue pipe connec tion with original angle pipe Connection dimensiones ...

Страница 4: ...4 Furnance door ...

Страница 5: ...5 Furnance Casing 55 54 ...

Страница 6: ...al combustion air feed 12 4 Operation Lighting the fire 13 Ash drawer 14 Operating the shaker grate 14 Rotary control knob 14 5 FITTING OPTIONS Changing flue pipe connection above to connection at rear 15 6 MAINTENANCE AND CLEANING General maintenance 16 Finish condition and cleaning 16 Convection air openings 16 Cleaning the flue gas channels 16 7 PROBLEM SOLVING What to do if 17 8 GUARANTEE AND ...

Страница 7: ...re 214 2 C Minimum flow pressure at rated heating ca pacity 12 Pa The owner of small firing systems or the person authorised for the small firing system is to keep the technical documentation and is to submit it to the authorities or the chimney sweep on request PARTS OVERVIEW Description 01 Furnance door machined Z33564 02 Door glass Z33465 03 Glass holder L00475 04 Lens head screw with ISK 10883...

Страница 8: ...bustion or introduction of highly flammable or explosive materials such as empty spray cans etc in the combustion chamber and storing them near the stove is strictly prohibited due to the danger of explo sion No light or inflammable clothing is to be worn when post heating Placing non heat resistant objects on the stove or near it is prohibited Do not place clothing on the stove to dry Stands for ...

Страница 9: ... fires BA 1 These fires must only be operated with the fire door closed 1 8 The fire door must only be opened for adding fuel and must then be closed again as this could otherwise lead to a danger to other fires that are also connected to the chimney 1 8 1 When the fire is not in operation the fire door must be kept closed 1 9 When using wet fuel and if operation is throttled too much the chimney ...

Страница 10: ...WOOD TYPES Different types of wood have different fuel values Decidu ous wood is particularly suitable It burns with a constant flame and forms long lasting embers Coniferous wood has higher levels of resin and burns off faster as do all soft woods and tends to spray sparks MAXIMUM FUEL QUANTITIES Wood 2 logs of approx 0 6 kg Wood briquettes broken 2 pieces of approx 0 6 kg The output of your stov...

Страница 11: ...mage or soiling of the fire and chimney as well as the environment 2 THE RIGHT QUANTITY OF FIREWOOD AND FIREWOOD DIMENSIONS Too much firewood leads to overheating This stresses the material too much and leads to poor flue gas values Too little firewood or logs being too large means the stove does not reach optimum operating temperature The flue gas values are also poor in this case The right quant...

Страница 12: ...nnection may not project into the chimney shaft Seal the gap between flue pipe and wall liner with ceramic sealer The installation must conform to the respective safety and building regulations Please contact your master chimney sweep in this context He will be pleased to inform you If you use a system chimney e g glazed fireclay we would ask you follow the manufacturer s connection instructions c...

Страница 13: ...olours pro duce very poisonous substances in the flue gas 3 Now light the paper Wait until the soft wood chips are burning well Close the shaker grate handle and the pri mary air slide a few minutes later Set the secondary air slide to the ideal setting a few minutes later 4 After this has burned lay approx 1 3 kg wood 2 billets on the fire Open the shaker grate handle and the primary air slide un...

Страница 14: ...heating loss of warranty Caution Embers could remain in the ash Only fill the ash into non flammable containers and do not put the ash onto flammable surfaces OPERATING THE SHAKER GRATE Page 4 Part 27 The ash is moved from the fire into the ash drawer by moving the shaker grate handle to and fro This frees up room for the primary feed air that is required for the heat ing phase in the fire The sha...

Страница 15: ...l part 46 using a hacksaw Please remember when changing the flue pipe connec tion that the individual parts of the soapstone panel ling weight about 34 kg In addition the surfaceof the soapstone should be protected to prevent scratching Swap the flue gas connector and the hob part 51 53 with each other Fit the new plate fins part 43 must be optionally or dered Make sure your fingers do not become ...

Страница 16: ...ss cleaner can be obtained from your special ist fire dealer Should the glass become heavily sooted the possible cause could be damp wood The fire finish is highly refractory and must only be cleaned using a cloth damp if necessary Only use original paint for touch up work this is available from your specialist dealer as an accessory Under no circumstances must the paint be cleaned before heating ...

Страница 17: ...y 2 Stove does not draw properly Chimney draught insufficient Stove is sooted over inside See A small study of heating See Maintenance and cleaning 3 Stove does not start burning properly Weather influence Incorrect heating up See Fire lighting See Fire lighting 4 Stove smells strongly and smokes outside Burning in phase Stove is dusty dirty See Operation curing of coating See Convection air openi...

Страница 18: ...at the time of purcha se Connection must be performed by a specialist for such stoves Any costs incurred by the manufacturer due to unjustified warranty claims are to be charged to the claimant Wear parts and parts affected by fire are excluded such as glass coating surface coatings e g handles panels seals fire trough grates draught plates deflector plates combustion chamber liners e g fireclay c...

Страница 19: ...19 ...

Страница 20: ...20 G U A R A N T E E G A R A N T I E Customer Client To A Stamp Marque Z33571 2011 05 05 ...

Отзывы: