3 . I N S T A L L A T I N G T H E F I R E
Before first commissioning or after changing the loca-
tion of the fire, cleaning and service work, ensure that
the flue plate, as well as the wood stop (Fig. Combus-
tion chamber, Part 47 and 31) is in the correct position.
When using a flue pipe with throttle valve, the throttle
valve must be open.
Care must be taken with this fire that the flue draught
reaches at least the prescribed value (> 10 Pa). Should
problems arise here, please contact your master chim-
ney sweep.
CONNECTING THE FIRE
Proceed as follows for new connections in a brick-built
chimney:
1. Measure and mark out the stove connection (take into
consideration any floor plate thickness) according to natu-
ral dimensions.
2. Chisel out (drill) the hole in the brickwork.
3. Brick in the wall liner.
First seal the wall lining using mineral wool insulation.
Afterwards plaster using heat resistant cement mortar
or equivalent.
4. After the mortar has hardened, and after plastering and
painting, position the floor plate including the floor pro
tection (carton).
5. The fire can now be lifted onto the floor plate carefully.
The stove should not be pushed on unprotected
floors.
Strong corrugated cardboard or e.g. old carpet is
useful to assist assembly and as a base. The stove
can also be pushed on this cardboard or carpet.
We recommend original flue pipes from RIKA for proper
connection.
The connection may not project into the chimney shaft!
Seal the gap between flue pipe and wall liner with ceramic
sealer.
The installation must conform to the respective safety
and building regulations.
Please contact your master chimney sweep in this
context. He will be pleased to inform you.
If you use a system chimney (e.g. glazed fireclay) we
would ask you follow the manufacturer’s connection
instructions closely.
MAKING AN EXTERNAL COMBUS-
TION AIR FEED
- Cut the perforated part from the rear panel by using a
saw blade (part 46).
- Remove the rear cover (part 60), (4 x Philips screw) and
replace it with the one shown in the illustration (air suction
connector obtainable from dealer Z32671).
- Tighten the non-flammable pipe Ø125 (e.g. steel spiral
pipe) and attach with a hose clip (not included in delivery!)
- The line should not be longer than 4 m and have no
bends in order to guarantee adequate air feed.
- Should the pipe lead into the open air it must end with a
vertical 90°-downward or with a cowl.
- If the stove is connected to an external combustion air
subbly, then the rotating assembly must be locked using a
fastening screw.
Note:
Please note that problems may arise due to updrafts in the
case of combustion air supply from an integrated chimney
ventilation shaft. If the combustion air flowing downwards
is heated it may rise and thus counter the chimney with a
resistance which in turn reduces the negative pressure in
the combustion chamber. The chimney manufacturer is to
guarantee that the resistance for the combustion air is a
maximum 2 Pa even in the least favourable operating state
of the chimney.
Содержание VITRA
Страница 1: ...1 VITRA Instruction manual ...
Страница 2: ...2 ...
Страница 3: ...3 Flue pipe connec tion with original angle pipe Connection dimensiones ...
Страница 4: ...4 Furnance door ...
Страница 5: ...5 Furnance Casing 55 54 ...
Страница 19: ...19 ...
Страница 20: ...20 G U A R A N T E E G A R A N T I E Customer Client To A Stamp Marque Z33571 2011 05 05 ...