|19
18
EN
9. PROBLEMS - POSSIBLE SOLUTIONS
Problem 1
Fire burns with weak, orange flame, window is sooted up�
Cause(s)
Q
Poor chimney draught
Q
Damp wood
Q
Incorrect heating up
Q
Stove is sooted over inside
Possible solutions
Q
Check whether flue gas pipes are blocked with ash
(see
CLEANING AND MAINTENANCE
)�
Q
Use dry wood and correct fuel amounts
(see
BRIEF INFORMATION ON COMBUSTIBLE - LOGS
)
Q
Check whether the suction nozzles and air inlet pipe or flue tube
are blocked�
Q
Check door and cleaning cover seals for leaks
(see
CLEANING AND MAINTENANCE
)
Q
Have service performed by authorised specialist company�
Q
Every glass plate must be cleaned from time to time (depending
on use) with glass cleaner�
Problem 2
Stove smells strongly and / or fumes are emitted�
Cause(s)
Q
Burning-in phase (taking into service)
Q
Stove has accumulated dust and/or dirt
Possible solution(s)
Q
Wait to end of burning-in phase and vent sufficiently
Q
Suction off any dust deposits from the convection air openings at
regular intervals
Problem 3
Flue gas discharge when wood is added and during heating phase�
Cause(s)
Q
Combustion chamber door opened too fast
Q
Too much ash in combustion chamber
Q
Adding logs to snappy
Q
Chimney draught too low
Q
Flue pipe connection leaks
Q
Logs combustion still running (visible flame)
Possible solution(s)
Q
open the combustion chamber door moderate
Q
regular cleaning of combustion chamber (vacuum)
Q
Adding logs carefully
Q
Check chimney
Q
Check connections and if necessary re-seal
Q
Add logs after flame is gone
Q
Check seals and replace (fire door, ��)
Содержание RIKATRONIC3 IMPOSA
Страница 1: ...Operating manual IMPOSA IMPOSA RIKATRONIC3...
Страница 22: ......
Страница 23: ...23 22 EN...