|15
14
EN
Status displays
LED display
Meaning
Action to be taken
The display lamp
flashes intermittently
RED
The stove has just been switched on and the
air flaps start the reference run�
The control system starts a reference run
again after a brief power failure�
The stove cannot heat up until the display
lamp stops flashing�
The display lamp is
constantly
RED
The combustion chamber is cold and the
stove is in neutral�
The combustion chamber temperature has
fallen below the temperature specified for
adding wood�
The stove is ready to heat up�
Optimum control process can no longer
be ensured, adding wood is not permitted�
The stove must be heated up again�
The display lamp is
constantly
GREEN
The stove is in normal operation�
The display lamp is
constantly
YELLOW
The stove is in ECO operation�
The display lamp
flashes regularly
RED
The temperature specified for adding wood
was not reached�
Open the combustion chamber door and
add a log or let the stove go out�
The display lamp
flashes regularly
GREEN
After the opening of the combustion
chamber door, the stove tries to light the
wood added�
The riddle grate should be open during
combustion as well as a lockable damper
clap in the flue pipe (if in use)�
The display lamp
flashes regularly
YELLOW
The ECO key was pressed after adding wood�
The magnetic switch sequence was initiated
See “Actions to be taken – flashes
regularly green”
See “Complete closing of the air flaps”