background image

26

15. DISPOSAL INFORMATION

RIKA Innovative Ofentechnik GmbH is ensuring that its products 
are eco-friendly throughout the product life cycle� This is why our 
commitment for electronic products goes beyond the end of their 
product life cycle�

Note

For proper disposal of the device, we recommend contacting a 
local waste disposal company�

Note

Please contact your RIKA specialist dealer for professional 
disassembly/dismantling of the device�

Note

We recommend that you remove the parts that come into contact 
with the fire, such as glass, fire trough, grates, draught plates, baffle 
plates, combustion chamber linings (e�g� fireclay), ceramics, ignition 
elements, sensors, combustion chamber sensors and temperature 
monitors and dispose of them in the household waste�

Information on the individual components 
of the device

 

Q

Electrical or electronic components:

 Remove the electrical or 

electronic components from the device by disassembling them� 
These components must not be disposed of in the residual waste� 
Proper disposal should be carried out via the waste electrical 
equipment take-back system� 

 

Q

Fireclay in the combustion chamber:

 Remove fireclay components 

that have been installed in the combustion chamber from the 
appliance� If present, fastening elements must be removed 
beforehand� Fireclay components that come into contact with 
the fire or flue gas must be disposed of; reuse or recycling is not 
possible�

 

Q

Vermiculite in the combustion chamber:

 Remove vermiculite 

that has been installed in the combustion chamber from the 
appliance� If present, fastening elements must be removed 
beforehand� Vermiculite in contact with fire or flue gas must be 
disposed of, reuse or recycling is not possible�

 

Q

Glass ceramic pane:

 Remove the glass ceramic pane using a 

suitable tool� Remove the seals and separate them from the frame 
if present� Transparent glass ceramic can generally be recycled, 
but must be separated into decorated and non-decorated panes� 
The glass ceramic pane can be disposed of as construction waste�

 

Q

Sheet steel:

 Disassemble the sheet steel components of the 

device by unscrewing or flexing (alternatively by mechanical 
crushing)� If present, remove the seals beforehand� Dispose of the 
sheet steel parts as metal scrap�

 

Q

Cast iron:

 Disassemble the components of the cast iron device 

by unscrewing or flexing (alternatively by mechanical crushing)� 
If present, remove gaskets beforehand� Dispose of the cast parts 
as metal scrap�

 

Q

Natural stone:

 Remove existing natural stone mechanically from 

the unit and dispose of as construction waste�

 

Q

Gaskets (glass fibre):

 Remove the gaskets mechanically from the 

device� These components must not be disposed of with residual 
waste, as waste glass fibre cannot be destroyed by incineration� 
Dispose of gaskets as glass and ceramic fibres (artificial mineral 
fibres)�

 

Q

Metal handles and decorative elements:

 If present, remove or 

dismantle metal handles and decorative elements and dispose 
of them as metal scrap�

Note

Please observe the local disposal possibilities for all components�

Extract from the waste code of the 
European Waste List Regulation

Waste code

Waste type

15 01 03

Wooden packaging

17 01 03

Tiles and ceramics

17 02 02

Glass

17 04 05

Iron and steel

17 05 04

Soil and stones

Electronic Waste

In accordance with the European Directive (2012/19/EU) Waste 
Electrical and Electronic Equipment (WEEE) and other local 
regulations, RIKA supports the setup of take-back systems and 
recycling infrastructures� 

Old devices can easily be returned to the municipal waste collectors 
for recycling purposes� Please observe the national regulations to 
that end�

The device may not be disposed of in the normal household waste� 

Содержание Revivo 125

Страница 1: ...Operating manual REVIVO 140 REVIVO 125...

Страница 2: ...ording to ENplus A1 15 Pellet container refilling during operation 15 Pellet storage 15 6 TECHNOLOGY AND SAFETY FUNCTIONS 16 Operating comfort 16 Top efficiency lowest emissions 16 Pressure monitoring...

Страница 3: ...20 Cleaning the flue pipes 21 Combustion air intake 21 Cleaning the convection air openings 21 Cleaning the pellet container 21 Checking door seal 21 Bearings 21 11 PROBLEMS POSSIBLE SOLUTIONS 22 Prob...

Страница 4: ...Model Identifier Equivalent models REVIVO 125 REVIVO 140 RIKA Innovative Ofentechnik GmbH Andreas Bloderer M llerviertel 20 4563 Micheldorf Austria Test report no Applied harmonised standards Other ap...

Страница 5: ...021 In case of doubt as well as missing or incorrect translations the German version is the only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innov...

Страница 6: ...0 10 19 20 17 30 23 25 24 24 26 27 16 28 29 1 6 21 22 2 2 5 3 4 4 44 44 51 50 32 32 33 52 34 34 37 38 36 49 53 53 41 42 43 41 42 43 41 42 43 36 44 35 35 45 46 31 48 47 39 40 39 40 3 TECHNICAL DATA Spa...

Страница 7: ...7 6 EN 64 65 66 60 61 59 61 67 62 63 58 68 69 70 71 56 57 75 81 87 91 90 85 89 88 85 86 85 93 94 82 84 83 79 92 77 78 76 80 74 73 95 96 97...

Страница 8: ...100 107 106 106 104 102 105 105 109 110 114 113 112 111 115 108 157 156 155 153 154 128 129 127 126 133 145 132 152 147 148 149 150 151 125 124 121 120 123 122 130 131 134 141 146 136 138 137 137 143...

Страница 9: ...9 8 EN Spare part overview exploded diagram REVIVO 125 173 160 168 172 171 170 169 166 163 165 164 161 167 174 175...

Страница 10: ...Detent plate 1 Z37054 Detent plate 48 N112393 Micro switch 49 N111950 Hexagonal screw M05x10 Nr Art Nr Description 50 N105179 Hexagonal nut M10 51 L03330 Washer 52 LB00701 Rail angle right 53 Z36778 B...

Страница 11: ...nting bracket 139 N112402 Rocker switch 140 N111604 Fuse 2 5 A 141 L03409 Support for drag chain 142 N112394 Chain 143 N112102 Differential pressure switch 144 N103990 Allen screw M04 x08 145 N111581...

Страница 12: ...ature C 148 Chimney draft requirement Pa 3 The capacity in kg may deviate due to different pellet bulk densities The owner of small firing systems or the person authorised for the small firing system...

Страница 13: ...on the stove to dry Q Laundry racks etc must be placed at a sufficient distance to the stove ACUTE DANGER OF FIRE Q When your stove is burning the use of highly inflammable and explosive materials in...

Страница 14: ...ustion chamber door is to be kept closed when the stove is not in operation Q Foulingofthechimneyi e depositsofhighlyinflammablematerials such as soot and tar and subsequently fire in the chimney may...

Страница 15: ...conducting measurements with a lignotester internal control Your pellet stove is only approved for the burning of pellets of tested quality Please ask your pellet stove dealer for tested fuel and a l...

Страница 16: ...acknowledging the error message at the internal unit Note Maintenance and cleaning work must be performed if overheating occurs If this error recurs operation without danger is no longer guaranteed n...

Страница 17: ...on must be calculated and shown with EN13384 1 and EN13384 2 Use only insulated double stainless steel tubes flexible aluminum or steel tubes are not permitted An inspection door for regular inspectio...

Страница 18: ...the heating times set at the stove can also be activated You can see whether the external demand is currently activated in the INFO main menu in submenu item Info inputs If your stove receives an ext...

Страница 19: ...ing cloth or newspaper Cleaning of the burn pot daily Make sure that the air vents are not blocked with ash or clinker Remove the clinker using the supplied brush and vacuum the burn pot The burn pot...

Страница 20: ...Resets menu Note Yourstovemustbeswitchedoffandcooledbeforeanymaintenance work is performed Only work on the unit when the mains plug has been disconnected Cleaning the flue gas channels Disconnect yo...

Страница 21: ...ush off any soot and dust deposits in the fire and in the flue pipes and vacuum Note Accumulated fly ash in the flue gas channels may impair the performance of the stove and pose a safety risk Combust...

Страница 22: ...G MAINTENANCE Problem 2 Stove smells strongly and smokes outside Cause s Q Burning in phase taking into service Q Stove has accumulated dust and or dirt Possible solutions Q Wait to end of burning in...

Страница 23: ...ions These are the basic stove functions that are to be checked and ticked off The stove is ready for operation if these functions are ensured Operator instruction This is one of the most important po...

Страница 24: ...eight Room ventilation Exhaust hood outdoor connection WC extraction Comments Central vacuum cleaning system YES NO YES NO YES NO YES NO Chimney draft full load Outside temperature Plaster openings YE...

Страница 25: ...ified for that type of stove The installation is performed by a RIKA certified technician If these points are not complied with the guarantee claim is void Any costs incurred by the manufacturer as a...

Страница 26: ...eramic pane using a suitable tool Remove the seals and separate them from the frame if present Transparent glass ceramic can generally be recycled but must be separated into decorated and non decorate...

Страница 27: ...27 26 EN...

Страница 28: ...only valid one Subject to technical and visual changes as well as layout and printing errors 2021 RIKA Innovative Ofentechnik GmbH Z37505_REVIVO_EN 7 12 2021 RIKA Innovative Ofentechnik GmbH M llervie...

Отзывы: