10. CLEANING
Depending on pellet consumption, a message prompting cleaning of
the stove appears on the display in regular intervals� This message
can be acknowledged on the Touch Display, while continuing
operation� Perform a cleaning cycle at the next opportunity�
Subsequently, reset the counter in the SETTINGS menu / RESETS
submenu, as per operating instructions of TOUCH DISPLAY�
Tip
The message will only stop reappearing once you have reset the
feed volume in the SETTINGS / Resets menu�
Note
Your stove must be switched off and cooled before any maintenance
work is performed� Only work on the unit when the mains plug has
been disconnected�
Cleaning the flue gas channels
Disconnect your appliance from the mains supply and remove the
lower convection grill�
Loosen the mechanical lock of the pull-out guide�
Extract the stove completely towards the front, securing it with a lock
screw on either side� Thus, the stove remains in extracted position for
maintenance works�
Remove the upper convection grill and the cover of the combustion
chamber�
Now clean the flues and baffles with the supplied brush� Vacuum the
combustion residues with a vacuum cleaner�